Description
AutoGCMS is a combination of two robust and miniaturised instruments, airmoVOC and/or ChromaFID and Det QMS, which allows quantification and identification of chemicals from high ppm to low ppt levels (depend on autoGC configuration) for VOCs, organosilane, odorants compounds. AutoGCMS integrate gas generators and calibration system for operation without any cylinder (in compliance with ISO 17025 for Benzene).
The analyzer is tested more than two weeks in our quality control department and then delivered and installed by our engineers. Once the instrument is set and running, the operators can easily control the air quality.
Vistachrom and Vista MS software enable users to view and store data on an industrial computer. It provides user friendly utilities to recalculate, calibrate and export data and to configure the measurement.
KEY POINTS
- Design to couple with 1 or multiple gas chromatography systems
- Miniaturization, sensitivity, mobility and flexibility are its main features. Everything, from primary vacuum pump until detector and electronics are in a 19“ in rack 12U.Complete system in compact cabinet with less than 1m2.
- Flexible analysis system for a broad range of applications
- Full automatic operation and easy to operate.
- Outstanding analytical performance
- Measurement of main components and trace components in gas mixtures in one step
- Measurements of chemical reactive and corrosive gas components possible
- Excellent long term stability and reproducibility of the analytical results
- High availability of data and automatic validation (at ppb or ppm level) thanks to internal permeation tube
- Low cost of ownership due to low maintenance
- Air monitoring by online Trap GC/FID/MS
- Identification of unknown compounds in SCAN mode with NIST library from ppt range
- Remote control installed and configurated into the computer for easy operation from remote location using internet connection
- Powerfull VISTACHROM Chromatotec® software:
- Remote monitoring & injection control
- Full traceability with on board archiving of results and chromatograms
- QC Set up and control of threshold alarms
- Time stamp results
- Stand By mode during transport in mobile van with 24 V DC option for very fast analysis when arrived on site
- Restart of the system in less than 60 minutes
Options
- On-line results are transmitted via a MODBUS / JBUS or MGS1 communication protocol
- Analog output: 4-20 mA or 0-10 V
- Multiple streams selector with up to 48 streams
- Purge and Trap for liquid samples
- Second airmoVOC or chromaFID for more compounds or future measurements
- 24 V DC power supply
- Specific inlet for sampling bag
- Alarm if instrument default by MODBUS or 4-20 mA
Review Auto GC-MS 866