AirmoVOC C6-C12

Heavy Volatile Hydrocarbons analyzer

  • Model: airmoVOC C6-C12
  • Manufacturer: Chromatotec

Analysis of up to 53 compounds from C6 to C12 and halogen compounds (TO14) or (PAMS)

Application

  • Urban/Non urban area pollution control
  • Indoor measurements
  • BTEX / PAMS / CE analysis
  • Plant / process emissions
  • Industrial Hygiene
  • Fence line monitoring
  • Wastewater plant, Purge and trap (method 502-2 or 524), Ambiant air control (PAMS and TO14)
Category:

The airmoVOC C6-C12 is designed for the measurement of volatile hydrocarbons compounds. It is capable of analyzing up to 53 compounds from C6 to C12 (PAMS, BTEX included) and halogenated compounds (TO14).

The instrument uses a 6-port valve with a single sorbent trap and a metallic capillary column. It is equipped with a flame ionization detector (FID). The column is installed in a programmable temperature gradient oven and the carrier gas is controlled by piezo-valve.

The airmoVOC C6-C12 is certified MCERTS for benzene measurement following EN 14662-3 norms.

Miniaturization, sensitivity, mobility and flexibility are its main features.

Everything from the sample port up to the data storage is integrated in a 19’’-rack 5U.

Before delivery the analyzer is tested for at least one week by our quality control department.

The Vistachrom software enables the user to visualize and store data on a PC. Furthermore, it enables the user to recalculate, calibrate and export data and to set-up measurement. The software allows the calculation of retention time, area, mass or concentration profiles.

Feature Specification
Detection Limit
– Tri-methylbenzene 10 ppt or 0.05 µg/m3
– Benzene 10 ppt in standard, 1 ppt with airmoVOC Expert
Detection Range
– Tri-methylbenzene and Benzene (amplification 3) 0.05 to 45 µg/m3
– Tri-methylbenzene and Benzene (amplification 2) 0.5 to 400 µg/m3
Relative Standard Deviation
– Time (RT) < 0.3% over 48 hours
– Concentration (Conc.) < 3% over 48 hours
Results Data storage
Data Communication (option) – 4-20mA current output
– MODBUS / JBUS or MGS1 communication protocol
Cycle Time 30 minutes (standard); 60 minutes (optional)
Gas Supply
– Hydrogen (FID and carrier gas): 30 ml/min
– Air (FID): 180 ml/min
Sample Inlet (vacuum pump) Standard
Sample Volume 30 to 700 ml (programmable) (sampling time up to 40 minutes)

airmoVOC C6C12 : Heavy Volatile Hydrocarbons analyzer

Download

Product reviews

Review AirmoVOC C6-C12

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review AirmoVOC C6-C12
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    ChromaTHC

    ChromaTHC

    Total HydroCarbons analysis
    Find out more
    chromaPID : BTEX analyzer with PID detector

    chromaPID

    BTEX analyzer with PID detector
    Find out more
    ChromaFID

    ChromaFID

    Volatile Organic Compounds (VOC) analyzer
    Find out more
    airTOXICBTX PID

    AirTOXIC BTX PID

    a GC/PID for automatic monitoring of BTEX in air, water or soil
    Find out more
    AirmoVOC BTEX MCERTS

    AirmoVOC BTX MCERTS

    A GC/FID instrument for automatic, continuous monitoring of BTEX in air, water or soil
    Find out more
    DET H2O

    DET H2O

    ELECTROLYTIC MOISTURE MONITOR HYGROMETER
    Moisture monitoring in gaseous samples for concentration between 30 ppb and 5000 ppm
    Find out more
    airmoCAL

    airmoCAL

    Calibration device inside 19ˮ and 4U/5U rack
    Find out more
    Purge and Trap

    airmoPUMP

    a sampling pump
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!