TPD Workstation

A system for UHV temperature programmed desorption (TPD/TDS) studies

  • Model: TPD Workstation
  • Manufacturer: Hiden Analytical

The Hiden TPD Workstation is a complete experimental system for UHV temperature programmed desorption (TPD) studies. The triple filter mass analyser is configured with a cooled shroud giving the analyser optimum sensitivity with minimum background contributions to desorption products from the sample. A fast sample load lock with sample transfer mechanism is included to provide for rapid sample change.

Features

  • Hiden 3F PIC Mass Spectrometer for fast data acquisition (>500 data points per second).
  • High sensitivity – requires a 1 cm2 sample for a complete analysis.
  • Multiport UHV chamber for attachment of additional instrumentation.
  • Linear sample transfer mechanism and loadlock, including gate valve and viewport.
  • Heated stage to 1000°C.
  • Sample stage Z-drive for optimum sample/detector positioning.
  • Bakeout Jacket (150°C max).
  • Integrated software control of experimental protocols including multistage heating commands.

Application

  • Catalysis
  • Thermal analysis MS
  • Surface science
  • Surface analysis
  • Nanotechnology
  • Fuel cells
Category:

The Hiden TPD Workstation is for UHV temperature programmed desorption (TPD) studies. The Workstation features a multiport UHV chamber with heated sample stage coupled to a high precision HAL 3F/PIC triple filter mass spectrometer with digital pulse ion counting detector for ultimate sensitivity and time resolution. The triple filter mass analyser is configured with a water-cooled shroud giving the analyser optimum sensitivity to desorption products from the sample. A fast sample load lock with transfer mechanism is included to provide for rapid sample change.

Hiden’s TPDsoft thermal analysis PC software provides for automatic control of sample temperature integrated with mass spectrometer control data acquisition and display. The software offers flexible experiment template setup including multiple stage experiments, with the heating ramp rate and data acquisition mode configurable for each stage of the experiment. Mass spectrometer data acquisition is acquired in multiple ion detection, MID, mode for selected peak monitoring or in histogram broad mass scan mode with 3D data presentation. Comprehensive TPD data analysis routines with peak de-convolution and integration for quantitative analysis are included. The TPD data together with experiment parameters are fully exportable, to Excel for example.

The 3F/PIC mass spectrometer includes a standard UHV low profile electron impact ioniser with twin oxide coated iridium filaments. A pulse ion counting single channel electron multiplier detector is included as standard. Pulse ion counting detection provides seven decades continuous dynamic range.

300 amu mass range is standard. Dual mass range capability for the mass spectrometer is available, providing high abundance sensitivity over the mass range to 50 amu, and is user configurable for 300 amu mass range operation when required. An option to extend the maximum mass range to 510 amu is available. Mass range options to 2500 amu are available on request.

The TPD Workstation is supplied in a compact bench unit.

The TDPWorkstation comprises

  • The Vacuum Chamber Module with: Multiport stainless steel spherical UHV analysis chamber including large view port, bakeout heaters, flanges and fittings.
  • The Analysis Chamber UHV Turbomolecular Pumping Set providing an ultra-high vacuum environment for TPD operation
  • Total pressure gauges for monitoring vacuum pump-down, vacuum integrity confirmation and interlock protection of the triple filter analyser in case of overpressure.
  • Fast sample transfer system, sample holder and manipulator
  • Heated sample stage
  • Mass Spectrometry: High performance Hiden 3F/PIC 301 RC mass spectrometer 300 amu mass range is standard.
  • TPDsoft thermal analysis PC software
  • Water cooled analyser shroud.
  • MASsoft Professional edition software.
  • UHV sample Z-drive for optimum sample/detector positioning.
  • Analysis Chamber UHV turbomolecular pumping set.
  • Independently pumped loadlock.
  • Vacuum chamber bakeout heaters.
System Dimensions: 1100 mm long x 725 mm deep x 1660 mm high.
Mass Spectrometer
HAL/ 3F 301 PIC Analyser, 300 amu with water cooled
shroud Mass Range : 300 amu
Mass Range options : 50 amu, 510 amu.
Mass Range options to 2500 amu available on request.
Maximum Operating Pressure : 5 x 10-6 mbar with PIC electron multiplier.
Resolution
50 amu system : 0.5 % Valley between adjacent peaks of equal height throughout the mass range.
300/510 amu system : 5 % Valley between adjacent peaks of equal

height throughout the mass range. Software adjustable.

Dual Detector : Fast pulse counting electron multiplier detector and optional Faraday cup detector.
Dynamic Range: 107 c/s continuous with the fast pulse ion counting electron multiplier detector
Measurement speed
Maximum measurement speed : 650 measurements per second.
650 measurements per second. Electron bombardment type, radially symmetric. Low-profile.
Filament : Two individual side mounting filaments.

Oxide coated iridium standard.

Electron emission : Software variable 1 µA to 2 mA.
Electron energy : Software variable 0 V to 150 eV.
Ion energy : Software variable 0 V to 10 eV.
PC Software Win 10, 7: TPDsoft Thermal Analysis Software and MASsoft Professional edition
Communications to PC : RS232, USB 2.0, 10/100 Base-T LAN.
Heated sample stage
Software controlled heated sample stage including temperature controller.

Typical sample size: 1 cm x 1 cm.

Variable ramp rate, maximum temperature 1000°C.

Sample top surface maximum temperature is sample type dependant.

Heating rates: up to 40°C/min

TPDsoft thermal analysis PC Software.
PC compatible software operating on a Windows® operating system. Comprehensive data acquisition and presentation routines are included.

Standard software features include:

  • Integrated software control of experimental protocols including sample temperature and MS data acquisition.
  • Multistage experiments with optimised data acquisition for each stage.
  • Multiple ion detection and Histogram mass scanning
  • Real time 3D data view to show mass scale, temperature /time and intensity on a single view
  • 3D Bar view is fully rotatable and expandable in real time allowing easier viewing of trends in mass data.
  • Trends can be extracted from histogram scan to give MS response vs temperature (or time) plot. Data output direct to excel
  • TPD analysis routines including peak integration/deconvolution.

Peak fitting function for de-convolution of overlapping peaks Output analysis to a test report.

Hiden TPD Workstation | A complete experimental system for UHV temperature programmed desorption (TPD) studies

Download

Product reviews

Review TPD Workstation

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review TPD Workstation
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    CATLAB-PCS

    CATLAB-PCS

    A system for catalyst characterisation, kinetic and thermodynamic measurements
    Find out more
    Hệ thống phân tích khí HPR-20 EGA

    HPR-20 EGA

    A compact bench-top gas analysis system for evolved gas analysis in thermogravimetric mass spectrometry, TGA-MS
    Find out more
    Hệ thống phân tích khí HPR-20 TMS

    HPR-20 TMS

    A specalist gas analysis system for fast event transient analysis
    Find out more
    máy khối phổ tứ cực

    3F PIC / 1000 Series PIC

    The quadrupole mass spectrometer for science applications
    Find out more
    Hệ thống khối phổ với tế bào điện hóa

    HPR-40 DEMS

    Solutions for Dissolved Gas Analysis and Off-gas Analysis in Electrochemistry
    Find out more
    Hệ thống nghiên cứu giải hấp nhiệt độ lập trình chân không cao

    TPD Workstation

    A system for UHV temperature programmed desorption (TPD/TDS) studies
    Find out more
    Hệ thống xác định hóa học xúc tác trong lò phản ứng

    SpaciMS

    A system for determination of intra catalyst reactor chemistry
    Find out more
    error: Content is protected !!