AirmoVOC C2-C6

Light Volatile hydrocarbons and 1,3-Butadiene analyzers

  • Model: airmoVOC C2-C6
  • Manufacturer: Chromatotec

Designed for analysis + monitoring of “light” hydrocarbons. It is used for the measurement of volatile hydrocarbon in the range of C2 to C6 i.e. from Ethane through 1,3-Butadiene up to Benzene (and other C6 compounds).

Application:

  • Urban / Non urban area pollution control
  • Indoor measurements
  • BTEX / PAMS / CE analysis
  • Plant / process emissions
  • Benzene, 1,3-butadiene
  • VOC screening of CO2 quality for the food and beverage industry
  • Industrial Hygiene
  • Fence line monitoring
  • Acetaldehyde/benzene
Category:

The airmoVOC C2-C6 is designed for the measurement of volatile hydrocarbons compounds from C2 to C6.

The instrument uses a 6-port valve with a single sorbent trap and a metallic capillary column. It is equipped with a flame ionization detector (FID). The column is installed in a programmable temperature gradient oven.

The airmoVOC C2-C6 uses a thermoelectric cooling system to control the temperature of the sample trap when required, for example for the analysis of ethyne.

It has a minimum detection level as low as 15 ppt (for 1,3-butadiene for e.g.) in ambient air, and can analyze up to 32 compounds during a single analysis.

Miniaturization, sensitivity, mobility and flexibility are its main features. Everything from the sample port up to the data storage is integrated in a 19″- rack 4U.

Before delivery, the analyzer is tested for at least one week by our quality control department.

The Vistachrom software enables the user to analyze and store data on a PC. It provides user friendly utilities to recalculate, calibrate, configure the measurement and export data. The software allows the calculation of retention time, area, mass or concentration profiles.

Detection Limit:

  • 15 ppt for 1,3-Butadiene or 33 ng/m3

Detection Range:

  • 0.5 to 100 PPB/amplification3 in standard

Relative Standard Deviation:

  • < 0.3 %over 48h (RT)
  • < 2 % over 48 h (Conc.)

Results:

  • Data storage
  • 4-20mA current output (option)
  • MODBUS / JBUS or MGS1 communication protocol (option)

Cycle time:

  • 30 min as standard (60 min optional)

Gas supply:

  • H2 (FID and carrier gas): 30 ml/min
  • Air (FID): 180 ml/min
  • Sample inlet (vacuum pump)
  • Pneumatic valve: 90ml/commutation

Sample volume:

  • 20 to 160 ml (programmable)(sampling time up to 40 minutes)
To order: Model:
airmoVOC C2-C6 (4U) (with internal cooling)

Needs a 5U supervisor

A11000
Supervisor (5U)

Chromatotec® computer 5U, LCD display,

Vistachrom software, 2 x RS232

XXX015

 

airmoVOC C2C6 : Light Volatile hydrocarbons and 1,3-Butadiene analyzers

Download

Product reviews

Review AirmoVOC C2-C6

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review AirmoVOC C2-C6
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    máy quang trắc ngọn lửa xung

    Pulsed Flame Photometric Detector (PFPD)

    Pulsed Flame Photometric Detector
    Find out more
    Máy đo độ đục để bàn Turb 750 T

    Turb 750 T Benchtop Turbidimeter

    Simplify turbidity measurements without compromising data quality
    Find out more
    Hệ thống phân tích dòng chảy liên tục

    Flow Solution FS3700

    Continuous Flow Analyzer
    Find out more
    máy đo màu cod 910

    910 COD Colorimeter

    Single Parameter Colorimeter for COD
    Find out more
    máy đo màu clo 900

    900 Chlorine Colorimeter

    Single Parameter Colorimeter for Total and Free Chlorine
    Find out more
    máy đo màu cầm tay

    pHotoFlex

    pHotoFlex Colorimeters
    Find out more
    máy quang phổ 9800

    9800 Photometer

    Portable & Multiparameter Photometer for Water Quality Testing
    Find out more
    ChromaTHC

    ChromaTHC

    Total HydroCarbons analysis
    Find out more
    error: Content is protected !!