Purge & Trap cabinet

Surveillance of VOC in water - BTEX included Based on EPA* 502.2 Method

  • Model: Purge & Trap cabinet
  • Manufacturer: Chromatotec

Application

  • Finished drinking water
  • Raw source water
  • Drinking water
  • Surface water
  • Wastewater (head space / ppt)
  • Rain water
  • Ambient air control
  • Urban/Non urban area pollution control
  • Indoor measurements
  • BTEX/PAMS/CE analysis
  • Finished water
  • Waste water / effluent
Category:

Principle

The airmoVOC 624 + DET QMS uses a valve with a sample trap. It also features a metallic capillary column.

  • Miniaturization, sensitivity, mobility and flexibility are its main features.
  • Everything from the sample port up to the data storage is integrated in a 19″- rack 5U for GC and 10U fo DET QMS.
  • Uninterrupted sampling with pre-concentration on 1 absorbent tube
  • Gas chromatograph with metallic column with programmable temperature gradient oven.

Pressure control of the carrier gas by piezo-valve.

  • One week tested after production for quality control.

Vistachrom software enables the user to visualize and store data on a PC.

Furthermore it provides comfortable utilities to recalculate, calibrate and export data and to set-up measurement.

The software allows the calculation of retention time, area, mass or concentration profiles.

Purge: for on line analytic instrument

  • Based on EPA 502.2 Method
  • 5 ml of water sample as standard or optional 25 ml sparger
  • Purge with inert gas: ultra pure N2 (Ultra High Purity) – 40 ml/min
  • Sampling time: 11 minutes • Dead volume < 15 mL (volume between water and trap)
  • Bubbles with a diameter < 3 mm at the origin of the frit
  • Automatic rinse (twice as standard)
Example of application
All VOC below can be analysed N° CAS
1,2-Dichloroethane 107-06-2
Benzene 71-43-2
1,2-Dichloropropane 78-87-5
Trichloroethylene 79-01.6
Toluene  108-88-3
Tetrachloroethylene  127-18-4
Chlorobenzene  108-90-7
Ethylbenzene 100-41-4
* m-Xylene 108-38-3
* p-Xylene  106-42-3
Styrene 100-42-5
All VOC below can be analysed N° CAS
o-Xylene 95-47-6
Isopropylbenzene 98-82-2
1,3,5-Trimethylbenzene 108-67-8
1,2,4-Trimethylbenzene 95-63-6  95-63-6
1,3-Dichlorobenzene 541-73-1
1,4-Dichlorobenzene 106-46-7
1,2-Dichlorobenzene 95-50-1
1,2,4-Trichlorobenzene 120-82-1
1,2,3-Trichlorobenzene 87-61-6
Hexachloro-1,3-butadiene 87-68-3
*SUM of M+P Xylene

Options

  • Automatic validation and calibration with internal CALIB
  • 24 V DC power supply
  • Integrated hydrogen and zero air generators for autonomous analysers
  • Multiplexer: 2 to 32 streams
  • 1 stream for water and 1 stream for air
  • Internal or external multipoint calibration and zero with CALIB MFC, XXXCYL MFC, airmoCAL PAH
  • airmoVOC C6C16 for more VOCs and S VOCs
  • Analog output 4-20 mA or 0-10 V
Analysis by airmoVOC 624 +DET QMS:
3 main solutions : Up to 60 compounds with our Purge & Trap 1 GC MS FID

  • BTEX and chlorine compounds
Detection limit:
  • < 0.05 µg/l for BTEX on FID and MS
Detection range:
  • 0.5 to 20 µg/l for surface water and finished drinking water
  • Other detection range in option
Relative standard deviation (RSD):
  • < 0.3% over 48h (Retention Time)
  • < 3% over 48h (Concentration)
  • < 10% for water analysis (Concentration)
Base Line: Zero drift:

< ±3%

Linearity:
  • R> 0.99 on all compounds
Supervisor:
  • Full result storage (data and chromatogram)
  • Embedded computer Windows® based with LCD display
  • 128 GB of Hardware storage on SSD memory
  • 4 USB Connecting Port
  • Two RS-232 ports
  • Display: 10’’ TFT Color LCD
  • MODBUS RTU / JBUS communication protocol
Cycle time:
  • 30 min to 60 min
Gas supply:
  • H2 (FID and carrier gas): 30 ml/min (inlet 2 bars ; 1/16’’ double ferrule)
  • Air (FID): 180 ml/min (inlet 2 bars ; 1/8’’ double ferrule)
  • N2 (Purge): 40 ml/min (inlet 3 bars ; 1/8’’ double ferrule)
  • Sample inlet (vacuum pump) ; 1/4double ferrule
Operation Temperature:
  • Room with air conditioning: 10 to 25°C
Purge:
  • ZERO N2 analysis
  • ZERO WATER analysis (Blank)
  • Standard water analysis
Power supply:
  • Main: 230V / 50 Hz or 115V / 60 Hz
Electrical consumption:
  • Mean: 150 VA + 1kVA (MS) + gas generators
Installation in a 19’’ 33U cabinet:
  • airmoVOC 624
  • DET QMS
  • Purge system
  • Nitrogen + hydrogen + air generators

 

TSP Purge & Trap

Download

Product reviews

Review Purge & Trap cabinet

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Purge & Trap cabinet
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    TDS LAB SERIES

    TDS LAB SERIES

    Advanced Thermal Desorption Spectrometry Systems
    Find out more
    máy quang trắc ngọn lửa xung

    Pulsed Flame Photometric Detector (PFPD)

    Pulsed Flame Photometric Detector
    Find out more
    Máy đo độ đục để bàn Turb 750 T

    Turb 750 T Benchtop Turbidimeter

    Simplify turbidity measurements without compromising data quality
    Find out more
    Hệ thống phân tích dòng chảy liên tục

    Flow Solution FS3700

    Continuous Flow Analyzer
    Find out more
    máy đo màu cod 910

    910 COD Colorimeter

    Single Parameter Colorimeter for COD
    Find out more
    máy đo màu clo 900

    900 Chlorine Colorimeter

    Single Parameter Colorimeter for Total and Free Chlorine
    Find out more
    máy đo màu cầm tay

    pHotoFlex

    pHotoFlex Colorimeters
    Find out more
    máy quang phổ 9800

    9800 Photometer

    Portable & Multiparameter Photometer for Water Quality Testing
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!