pQA portable gas analyser

Designed for analysis of dissolved gases in water, and sediments for use in the field at the riverbank, on boats and in mobile laboratories

  • Model: pQA
  • Manufacturer: Hiden Analytical

The Hiden pQA portable gas analyser is a versatile mass spectrometer and offered with a range of interchangeable sampling inlets to suit a broad application range. MIMS inlets are offered for analysis of dissolved species in ground water, sediments, fermentation cultures, soil samples, and general applications where analysis of dissolved species in liquid sample is required. The system is suited to gas analysis applications, where sample volume is small, and for environmental applications where detection of low concentration levels is required.

Applications

  • Dissolved Species Analysis
  • Green Hydrogen
  • Environmental Monitoring
  • Fuel Cells
  • Volcanic Gas, Water and Sediment Analysis
  • Biogas
  • Denitrification Studies
  • Groundwater Studies
  • Wastewater & Sludge Analysis
Category:

The pQA system has a mass range of 200 amu and sub ppb detection levels. Extended mass range to 300amu is optional.

The system is supplied in a Pelican case, and can be powered by a 12 V supply for field use or a 220 V supply for laboratory use.

Sampling inlet systems are offered for a broad application range including:

  • Direct membrane inlet probe for immersion and/or insertion in liquid or sludge sample, soil core sampling for example.
  • Recirculating probe for analysis of sample with continuous flow, extracted sea or estuary water for example.
  • Flow through probe, low flow design for denitrification studies. 

The system includes

  • Quadrupole mass spectrometer system from the RGA series with mass range options 200 amu.
  • Mass spectrometer analyser manifold and UHV pump set with a manually valved dissolved species probe with silicone rubber membrane.
  • Ion Gauge and interlocks to provide protection for the mass spectrometer in case of over pressure.
  • Fast acting shut off valve between the dissolved species probe and mass spectrometer manifold to protect the mass spectrometer in case of membrane failure. The valve is interlocked with the integral UHV pressure gauge.
  • Supplied in a ruggedized Pelican case for usability in the field.
  • Can be powered by a 12 V supply, from a vehicle power outlet, for example.
  • Can also be powered by a standard power outlet for laboratory use.
  • Total weight is less than 40 kg.

pQA – Portable Quadrupole Analyser

Download

Product reviews

Review pQA portable gas analyser

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review pQA portable gas analyser
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    TDS LAB SERIES

    TDS LAB SERIES

    Advanced Thermal Desorption Spectrometry Systems
    Find out more
    HPR-20 OEMS

    HPR-20 OEMS

    for continuous analysis of evolved gases and vapours in electrochemistry
    Find out more
    công nghệ vật liệu nano fib sims

    FIB-SIMS

    Add high performance SIMS capability to your existing FIB system
    Find out more
    CATLAB-PCS

    CATLAB-PCS

    A system for catalyst characterisation, kinetic and thermodynamic measurements
    Find out more
    Hệ thống phân tích định lượng các thành phần của khí

    QGA 2.0

    Quantitative gas analyser
    Find out more
    Hệ thống phân tích khí chuyên sâu

    The HPR-20 R&D Gas Analysis System

    A specialist gas analysis system for applications that require high sensitivity, selectivity, and fast response
    Find out more
    Hệ thống phân tích khí HPR-20 EGA

    HPR-20 EGA

    A compact bench-top gas analysis system for evolved gas analysis in thermogravimetric mass spectrometry, TGA-MS
    Find out more
    Hệ thống phân tích khí HPR-20 TMS

    HPR-20 TMS

    A specalist gas analysis system for fast event transient analysis
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!