Features

  • 500 … 1100 hPa or 50 …. 1100 hPa pressure ranges with serial output
  • Different scalings between 500 … 1100 hPa with analog output
  • Electronics housing IP65 protected against sprayed water
  • Accurate and stable measurement
  • NIST traceable (certificate included)
Category:

 For harsh environments

The Vaisala BAROCAP® Digital Barometer PTB210 is ideal for outdoor installations and harsh environments. The barometers are designed to operate in a wide temperature range, and the electronics housing provides IP65 (NEMA 4) standardized protection against sprayed water.

Excellent hysteresis and repeatability characteristics

The PTB210 barometers use the Vaisala BAROCAP® Sensor, a silicon capacitive absolute pressure sensor developed by Vaisala for barometric pressure applications. The Vaisala BAROCAP® Sensor provides also outstanding temperature and long-term stability

Several pressure ranges

The PTB210 barometers are designed for various pressure ranges. They are available in two basic configurations: serial output for 500 … 1100 hPa and 50 … 1100 hPa and analog output with different scalings between 500 … 1100 hPa.

Vaisala BAROCAP technology

PTB210 uses the Vaisala BAROCAP sensor, a silicon capacitive absolute pressure sensor developed by Vaisala for barometric pressure applications.The Vaisala BAROCAP sensor provides excellent hysteresis and repeatability characteristics and outstanding temperature and long-term stability. PTB210 is delivered with a traceable factory calibration certificate.

Measurement performance

Pressure range

Serial output 500 … 1100 hPa 

50 … 1100 hPa

Analog output 500 … 1100 hPa 

600 … 1060 hPa 

800 … 1060 hPa 

900 … 1100 hPa

 

Serial output, accuracy (hPa)
Pressure range 500 … 1100 50 … 1100

 

Class A Class B
Non-linearity 1)  ± 0.10 ± 0.15 ± 0.20
Hysteresis 1) ± 0.05 ± 0.05 ± 0.10
Repeatability 1) ± 0.05 ± 0.05 ± 0.10
Calibration uncertainty 2) ± 0.07 ± 0.15 ± 0.20
Accuracy at +20 °C (+68 °F) 3) ± 0.15 ± 0.20 ± 0.35
Temperature dependency 4) ± 0.20 ± 0.20 ± 0.40
Total accuracy -40 … +60 °C (-40 … +140 °F) 3)  ± 0.25 ± 0.30 ± 0.50
Long-term stability (hPa/ year) ± 0.10 ± 0.10 ± 0.20

 

Analog output, accuracy

 

Non-linearity 1) ± 0.20 hPa
Hysteresis 1) ± 0.05 hPa
Repeatability 1) ± 0.05 hPa
Calibration uncertainty 2) ± 0.15 hPa
Accuracy at +20 °C (+68 °F) 3) ± 0.30 hPa
Temperature dependency 4) ± 0.50 hPa
Total accuracy -40 … +60 °C (-40 … +140 °F) 3) ± 0.60 hPa
Long-term stability ± 0.10 hPa/year

 

1) Defined as the ±2 standard deviation limits of end point non-linearity, hysteresis error, or repeatability error. 

2) Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to international standards. 

3) Defined as the root sum of the squares (RSS) of end point non-linearity, hysteresis error, repeatability error, and calibration uncertainty at room temperature. 

4) Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. 

 

Operating environment

 

Operating temperature −40 … +60 °C (−40 … +140 °F)
Operating humidity 0 … 100 %RH, non‑condensing

 

Compliance

 

Directives EMC Directive (2014/30/EU) RoHS Directive (2011/65/EU)
EMC compatibility EN / IEC 61326-1, Electrical equipment for measurement, control and laboratory use – EMC requirement; Basic environment CISPR 32 / EN 55032, Class B
Compliance  CE, FCC, UKCA 

 

Mechanical specifications

 

Housing material PC plastic
IP rating, electronics IP65 (NEMA 4)
IP rating, sensor IP53
Weight, sensor 110 g (3.9 oz)
Cable weight 28 g/m (1.0 oz)

 

Inputs and outputs 

 

Serial output
Shutdown ON/OFF 
Settling time at startup 2 s
Serial I/O RS-232C 

RS-232C / TTL (optional) 

RS-485, non-isolated (optional)

Parity None, even, odd
Data bits 7, 8
Stop bits 1, 2
Baud rate 1200, 2400, 4800, 9600, 19200
Response time 1 s
Resolution 0.01 hPa (1 measurement/s) 

0.03 hPa (10 measurements/s)

Current consumption, normal mode < 15 mA (factory setting)
Current consumption, shutdown mode 0.2 mA
Analog output
Outputs 0 … 5 V DC, 0 … 2.5 V DC 

(order specified)

Shutdown ON/OFF
Response time 500 ms
Resolution 300 μV
Measurement rate 3 measurements/s
Current consumption, normal mode < 8 mA
Current consumption, shutdown mode 0.2 mA
All models
Max. pressure 5 000 hPa absolute
Pressure connector M5 (10-32) internal thread
Pressure fitting Barbed fitting for 1/8 in I.D. tubing
Supply voltage (reverse polarity protected), with RS-232/TTL output 5 … 28 V DC
Supply voltage (reverse polarity protected), with RS-485 or analog output 8 … 18 V DC

 

BAROCAP® Digital Barometer PTB210 Datasheet

Download

Product reviews

Review PTB210 Digital Barometer

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review PTB210 Digital Barometer
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Bộ thu thập và xử lý dữ liệu Granite 10

    Granite 10 Measurement and Control Data-Acquisition System

    Ideal for automotive testing applications, featuring CAN bus and CAN FD output
    Find out more
    Mô-đun Đầu vào Cổng Dòng điện 100 Ohm CURS100

    CURS100 100-Ohm Current Terminal Input Module

    Expands capabilities, allows data logger to measure additional types of sensors
    Find out more
    Datalogger ba kênh cho cảm biến dây rung CRVW3-NE

    CRVW3-NE Three-Channel Vibrating Wire Datalogger without Enclosure

    Vibrating Wire Data Logger Using patented VSPECT™ technology
    Find out more
    Bộ Ghi Dữ Liệu Dây Rung Ba Kênh CRVW3

    CRVW3 Three-Channel Vibrating Wire Datalogger

    Self-Contained Vibrating Wire Data Logger Using patented VSPECT® technology
    Find out more
    Bộ ghi đo tự động Datalogger CR6

    CR6 Automated Monitoring Platform

    Rugged, wireless edge device and gateway with built-in connectivity, designed for geotechnical, structural, and environmental projects
    Find out more
    Bộ ghi dữ liệu đo lường và điều khiển CR350

    CR350 Measurement and Control Datalogger

    Compact data logger with RS-485, ideal for small applications
    Find out more
    Bộ ghi dữ liệu đo lường và điều khiển CR310

    CR310 Measurement and Control Datalogger

    Compact data logger with ethernet, ideal for small applications
    Find out more
    Bộ ghi dữ liệu đo lường và điều khiển CR300

    CR300 Measurement and Control Datalogger

    Compact data logger, ideal for small applications
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!