CR1000 – Measurement and Control Datalogger
Operating Temperature Range |
- -25° to +50°C (standard)
- -55° to +85°C (extended)
- Non-condensing environment
|
Analog Inputs |
16 single-ended or 8 differential (individually configured) |
Pulse Counters |
2 |
Voltage Excitation Terminals |
3 (VX1 to VX3) |
Communications Ports |
- CS I/O
- RS-232
- Parallel peripheral
|
Switched 12 Volt |
1 terminal |
Digital I/O |
- Certain digital ports can be used to count switch closures.
- 8 I/Os or 4 RS-232 COM
I/O ports can be paired as transmit and receive for measuring smart serial sensors.
|
Input Limits |
±5 Vdc |
Analog Voltage Accuracy |
±(0.06% of reading + offset) at 0° to 40°C |
ADC |
13-bit |
Power Requirements |
9.6 to 16 Vdc |
Real-Time Clock Accuracy |
±3 min. per year (Correction via GPS optional.) |
Internet Protocols |
FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP |
Communication Protocols |
PakBus, Modbus, DNP3, SDI-12, SDM |
Warranty |
3 years |
Battery-backed SRAM for CPU Usage & Final Storage |
4 MB |
Idle Current Drain, Average |
< 1mA (@ 12 Vdc) |
Active Current Drain, Average |
- 1 mA (1 Hz sample rate @ 12 Vdc without RS-232 communication)
- 16 mA (100 Hz sample rate @ 12 Vdc without RS-232 communication)
- 28 mA (100 Hz sample rate @ 12 Vdc with RS-232 communication)
|
Dimensions |
- 23.8 x 10.1 x 5.4 cm (9.4 x 4.0 x 2.1 in.)
- 25.2 x 10.2 x 7.1 cm (9.9 x 4.0 x 2.8 in.) with CFM100 or NL116 attached
|
Weight |
1.0 kg (2.1 lb) |
CS305-ET | Solar Radiation Sensor for ET107 Stations
Light Spectrum Waveband |
300 to 1100 nm |
Measurement Range |
0 to 2000 W m-2 (full sunlight ≈ 1000 W m-2) |
Absolute Accuracy |
±5% for daily total radiation |
Sensitivity |
0.2 kW m-2 mV-1 |
Cosine Response |
- ±4% (at 75° zenith angle)
- ±1% (at 45° zenith angle)
|
Temperature Response |
< 1% (at 5° to 40°C) |
Long-Term Stability |
< 2% per year |
Diameter |
2.4 cm (0.9 in.) |
Cable Length |
152.4 cm (60 in.) |
Height |
2.5 cm (1.0 in.) |
Weight |
65 g (2.3 oz) |
HMP60-ETS | Temperature/RH Probe for ET Station with Shield Adapter
Supply Voltage |
5 to 28 Vdc (typically powered by datalogger’s 12 V supply) |
Typical Current Consumption |
1 mA |
Maximum Current Consumption |
5 mA |
Filter Description |
0.2 µm Teflon membrane |
Settling Time |
1 s |
Sensor Body Material |
AISI 316 stainless steel |
Filter Cap Material |
Chrome-coated ABS plastic |
Classification |
IP65 |
Filter Diameter |
1.2 cm (0.5 in.) |
Sensor Diameter |
1.2 cm (0.5 in.) |
Sensor Length |
7.1 cm (2.8 in.) |
Cable Length |
137.16 cm (54 in.) |
Weight |
117.93 g (0.26 lb) |
Temperature
|
Temperature Sensor |
1000 ohm Platinum Resistance Thermometer |
Measurement Range |
-40° to +60°C |
Accuracy |
±0.6°C |
Relative Humidity
|
Sensor |
Vaisala’s INTERCAP capacitive chip |
Measurement Range |
0 to 100% RH (non-condensing) |
Accuracy (0 to 90% RH) |
- ±5% (-40° to 0°C)
- ±3% (0° to 40°C)
- ±5% (40° to 60°C)
|
Accuracy (90 to 100% RH) |
- ±7% (-40° to 0°C)
- ±5% (0° to 40°C)
- ±7% (40° to 60°C)
|
TE525-ET | Rain Gage with 6 in. Orifice for ET Station
Sensor Type |
Tipping bucket/magnetic reed switch |
Material |
Anodized aluminum |
Temperature |
0° to 50°C |
Resolution |
1 tip |
Volume per Tip |
4.73 ml/tip (0.16 fl. oz/tip) |
Rainfall per Tip |
0.254 mm (0.01 in.) |
Accuracy |
1.0% up to 2 in./h (50 mm/h) |
Cable |
2-conductor shielded |
Funnel Collector Diameter |
15.4 cm (6.06 in.) |
Height |
24.1 cm (9.5 in.) |
Cable Length |
139.7 cm (55 in.) |
Tipping Bucket Weight |
0.9 kg (2.0 lb) |
Cable Weight |
0.1 kg (0.2 lb) per 3.05 m (10 ft) length |
034B-ET | Wind Set for ET Station
Operating Temperature |
-30° to +70°C |
Cable Length |
170.18 cm (67 in.) |
Weight |
907 g (2 lb) |
Wind Speed (Anemometer)
|
Range |
0 to 75 m/s (0 to 167 mph) |
Accuracy < 10.14 m/s (22.7 mph) |
0.1 m/s (0.25 mph) |
Accuracy > 10.14 m/s (22.7 mph) |
±1.1% of true |
Resolution |
(0.7998 m s-1) / (scan rate in seconds) or (1.789 mph) / (scan rate in seconds) |
Starting Threshold |
0.4 m/s (0.9 mph) |
Sensor Output |
Pulsed contact closure |
Anemometer Radius |
10.7 cm (4.2 in.) |
Anemometer Height |
24.4 cm (9.6 in.) |
Wind Direction (Vane)
|
Mechanical Range |
360° |
Electrical Range |
356° (4° open) |
Accuracy |
±4° |
Damping Ratio |
0.25 |
Resolution |
< 5° |
Potentiometer Resistance |
0 to 10 kΩ (open at crossover) |
Vane Length |
33.5 cm (13.2 in.) |
WINDSONIC1-ET | 2-D Sonic Wind Sensor with RS-232 Output for ET107 Station
Operating Humidity |
< 5% to 100% RH |
Operating Temperature |
-35° to +70°C |
Storage Temperature |
-40° to +80°C |
Input Voltage |
9 to 30 Vdc |
Typical Current Drain |
~15 mA (continuous) |
Measurement Frequency |
40 Hz block averaged to a 1 Hz output frequency |
Outputs Parameters |
Polar (direction and speed) or orthogonal (Ux and Uy wind) |
Output Signal |
RS-232 |
Maximum Cable Capacitance |
2500 pF |
Maximum Cable Length |
15.24 m (50 ft)
For configurations requiring longer cable lengths, contact an application engineer at Campbell Scientific. |
Diameter |
14.2 cm (5.6 in.) |
Length |
16.0 cm (16.3 in.) |
Weight |
0.5 kg (1.1 lb) |
Wind Direction
|
Range |
0° to 359° (no dead band) |
Accuracy |
±3° |
Resolution |
1° |
Wind Speed
|
Range |
0 to 60 m/s |
Accuracy |
±2% (@ 12 m s-1) |
Resolution |
0.01 m/s |
WINDSONIC1-ET | 2-D Sonic Wind Sensor with RS-232 Output for ET107 Station
Operating Humidity |
< 5% to 100% RH |
Operating Temperature |
-35° to +70°C |
Storage Temperature |
-40° to +80°C |
Input Voltage |
9 to 30 Vdc |
Typical Current Drain |
~15 mA (continuous) |
Measurement Frequency |
40 Hz block averaged to a 1 Hz output frequency |
Outputs Parameters |
Polar (direction and speed) or orthogonal (Ux and Uy wind) |
Output Signal |
RS-232 |
Maximum Cable Capacitance |
2500 pF |
Maximum Cable Length |
15.24 m (50 ft)
For configurations requiring longer cable lengths, contact an application engineer at Campbell Scientific. |
Diameter |
14.2 cm (5.6 in.) |
Length |
16.0 cm (16.3 in.) |
Weight |
0.5 kg (1.1 lb) |
Wind Direction
|
Range |
0° to 359° (no dead band) |
Accuracy |
±3° |
Resolution |
1° |
Wind Speed
|
Range |
0 to 60 m/s |
Accuracy |
±2% (@ 12 m s-1) |
Resolution |
0.01 m/s |