D12 Toxic and Combustible Gas Detector

A versatile, toxic and flammable gas detector compatible with up to 46 different sensors

Key benefits

  • Multiple configurations including: Loop Powered Transmitter, Loop Powered with HART™, Transmitter with Integral Relays and Transmitter with Modbus™
  • Explosion Proof Enclosure
  • Internal Data Logger

Applications

  • Chemical Processing
  • Pulp & Paper
  • R&D Labs
  • Semiconductor Plants
  • Refineries
  • Pharmaceuticals
  • Food Processing
  • Aluminum Refining
  • Breweries
  • Metals Processing
  • Water Treatment
  • Wastewater Treatment
  • Electric Utilities
  • Agricultural Chemicals
  • Plastics Manufacturing
Category:

ATi’s D12 digital gas detector is a flexible, toxic and combustible gas detector that is compatible with up to 46 different sensors.

Fixed, toxic gas detector

The D12 digital gas detector is a flexible, toxic and combustible gas detector that accepts up to 46 different sensors, reducing the requirement of multiple transmitter models.

The self-aligning sensor holder simply plugs in, with automatic sensor recognition and verification when contact is made.

The unique sensor response testing system provides reliable response checks to insure system integrity, which includes outdoor weather conditions. The sensor response is verified with an actual gas sample, generated on demand. Generators store run time information accessible to operators, and are automatically tested for compatibility with the installed sensor.

Features & specification

  • Backlit LCD Display
  • Non-Intrusive operating functions such as calibration, alarm setup, alarm reset, data view, and setup
  • Options are all available using a magnetic tool.
  • No need to open the enclosure when making adjustments.
  • Password Protection
  • Modular Electronics
  • Scalable 4-20 mA: The output range for a particular sensor is programmable within the range boundaries set in that sensor.
  • Three Internal Alarm Relays
  • Analog Output Simulation
  • Relay Output Simulation
  • Serial Communication Interface

Available Gas List

Symbol Gas Min. Range Max. Range
C₂H₂ Acetylene * 0-50 PPM 0-500 PPM
HX Acid Gases * 0-10 PPM 0-200 PPM
C₂H₅OH Alcohol 0-50 PPM 0-2000 PPM
NH₃ Ammonia * 0-50 PPM 0-2000 PPM
AsH₃ Arsine 0-500 PPB 0-2000 PPB
Br₂ Bromine * 0-1 PPM 0-200 PPM
CO Carbon Monoxide * 0-50 PPM 0-1000 PPM
Cl₂ Chlorine * 0-1 PPM 0-200 PPM
ClO₂ Chlorine Dioxide * 0-1 PPM 0-200 PPM
CH₄ Combustible Gas * 0-50% LEL 0-100% LEL
B₂H₆ Diborane 0-500 PPB 0-2000 PPB
C₂H₄O Ethylene Oxide * 0-20 PPM 0-500 PPM
F₂ Fluorine * 0-1 PPM 0-200 PPM
HCHO Formaldehyde * 0-20 PPM 0-200 PPM
GeH₄ Germane 0-500 PPB 0-2000 PPB
H₂ Hydrogen 0-500 PPM 0-10%
HCl Hydrogen Chloride * 0-10 PPM 0-200 PPM
HCN Hydrogen Cyanide * 0-10 PPM 0-200 PPM
HF Hydrogen Fluoride * 0-10 PPM 0-200 PPM
H₂O₂ Hydrogen Peroxide 0-10 PPM 0-1000 PPM
H₂Se Hydrogen Selenide 0-500 PPB 0-2000 PPB
H₂S Hydrogen Sulfide * 0-10 PPM 0-200 PPM
I₂ Iodine * 0-5 PPM 0-20 PPM
NO Nitric Oxide 0-50 PPM 0-200 PPM
NO₂ Nitrogen Dioxide * 0-10 PPM 0-200 PPM
O₂ Oxygen 0-5% 0-25%
O₃ Ozone * 0-1 PPM 0-20 PPM
COCl₂ Phosgene 0-1 PPM 0-20 PPM
PH₃ Phosphine 0-500 PPB 0-2000 PPB
SiH₄ Silane 0-10 PPM 0-200 PPM
SO₂ Sulfur Dioxide * 0-10 PPM 0-200 PPM

(*) Auto-Test gas generator available.

Specifications

Attribute Details
Gas Type Selected by customer from available sensor list.
Sensor Type Electrochemical for toxic gases and oxygen. Catalytic bead for combustible gas.
Range User adjustable within limits of selected sensor.
Response Time Sensor dependent
Accuracy Generally ±10% of value (limited by available calibration gas)
Repeatability ±1% (Electronic)
Linearity ±0.5% (Electronic)
Zero Drift Less than 2% full scale per month, non-cumulative
Span Drift Dependent on environment but generally less than 3% per month
Alarms Three concentrations alarms (Caution, Warning, Alarm), programmable for setpoint, hysteresis, alarm delay, and manual or automatic reset. One fault alarm with programmable output and relay response.
Analog Output Loop-powered 4-20 mA, 675 ohms maximum at 24 VDC
Serial Interface HART™ (1200 baud modem interface), MODBUS™ (1200-9600 – RS232 or RS485, software selectable)
Power 12 – 30 VDC, 25 mA maximum in loop-powered mode. 12 – 30 VDC, 200 mA maximum in 3-wire mode.
Alarm Relays Three SPDT, 5 A @ 230 VAC resistive load
Relay Coil Programmable as either normally energized or normally de-energized
Enclosure Explosion-proof, Class 1, Div. 1, Groups B, C, & D
Sensor Auto-Test Optional gas generator dependent on sensor
Controls 4 magnetic switches on front of transmitter
Operating Temp. -30° to +60°C for toxics (-10°C minimum for O₂ sensor), -40° to +70°C for combustibles
Weight 4 lbs (1.8 kg)

Toxic Gas Sensors

Part No. Gas & Range
00-1000 Bromine, 0-1/5 PPM (2 PPM Standard)
00-1001 Bromine, 0-5/200 PPM (20 PPM Standard)
00-1002 Chlorine, 0-1/5 PPM (2 PPM Standard)
00-1003 Chlorine, 0-5/200 PPM (20 PPM Standard)
00-1004 Chlorine Dioxide, 0-1/5 PPM (2 PPM Standard)
00-1005 Chlorine Dioxide, 0-5/200 PPM (20 PPM Standard)
00-1006 Fluorine, 0-1/5 PPM (2 PPM Standard)
00-1007 Fluorine, 0-5/200 PPM (20 PPM Standard)
00-1008 Ozone, 0-1/5 PPM (2 PPM Standard)
00-1009 Ozone, 0-5/200 PPM (20 PPM Standard)
00-1010 Ammonia, 0-50/200 PPM (200 PPM Standard)
00-1011 Ammonia, 0-500/2000 PPM (2000 PPM Standard)
00-1012 Carbon Monoxide, 0-50/1000 PPM (200 PPM Standard)
00-1013 Hydrogen, 0-1/10% (4% Standard)
00-1014 Oxygen, 0-5/25% (25% Standard)
00-1015 Phosgene, 0-1/5 PPM (2 PPM Standard)
00-1016 Phosgene, 0-5/100 PPM (100 PPM Standard)
00-1017 Hydrogen Chloride, 0-1/200 PPM (20 PPM Standard)
00-1018 Hydrogen Cyanide, 0-1/200 PPM (20 PPM Standard)
00-1019 Hydrogen Fluoride, 0-1/200 PPM (20 PPM Standard)
00-1020 Hydrogen Sulfide, 0-1/200 PPM (20 PPM Standard)
00-1021 Nitric Oxide, 0-50/200 PPM (200 PPM Standard)
00-1022 Nitrogen Dioxide, 0-10/200 PPM (20 PPM Standard)
00-1023 Sulfur Dioxide, 0-10/500 PPM (20 PPM Standard)
00-1024 Arsine, 0-100/2000 PPB (1000 PPB Standard)
00-1025 Diborane, 0-500/2000 PPB (1000 PPB Standard)
00-1026 Diborane, 0-10/200 PPM (20 PPM Standard)
00-1027 Germane, 0-500/2000 PPB (1000 PPB Standard)
00-1028 Germane, 0-10/200 PPM (20 PPM Standard)
00-1033 Hydrogen Selenide, 0-500/2000 PPB (1000 PPB Standard)
00-1034 Phosphine, 0-50/2000 PPB (1000 PPB Standard)
00-1035 Phosphine, 0-500/2000 PPM (1000 PPM Standard)
00-1036 Iodine, 0-1/5 PPM (2 PPM Standard)
00-1037 Acid Gases, 0-10/200 PPM (20 PPM Standard)
00-1038 Ethylene Oxide, 0-20/500 PPM (20 PPM Standard)
00-1039 Formaldehyde, 0-20/200 PPM (20 PPM Standard)
00-1042 Hydrogen, 0-500/2000 PPM (2000 PPM Standard)
00-1043 Hydrogen Peroxide, 0-10/1000 PPM (200 PPM Standard)
00-1044 Sulfur Dioxide, 0-10/500 PPM (20 PPM Standard)
00-1045 Alcohol, 0-50/500 PPM (200 PPM Standard)
00-1046 Alcohol, 0-500/2000 PPM (2000 PPM Standard)
00-1057 Acetylene, 0-500/2000 PPM (500 PPM Standard)

Thiết bị phát hiện khí độc D12

Download

Product reviews

Review D12 Toxic and Combustible Gas Detector

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review D12 Toxic and Combustible Gas Detector
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Thiết bị giám sát Sulfide Q46S/81

    Q46S/81 Dissolved Sulfide Monitor

    Provides an improved method for measuring sulfides in solution
    Find out more
    Thiết bị giám sát độ dẫn điện kiểu Toroidal Q46CT

    Q46CT Toroidal Conductivity Monitor

    Meet virtually any conductivity water quality monitoring and control application
    Find out more
    Thiết bị giám sát Ozone hòa tan trong nước Q46H/64

    Q46H/64 Dissolved Ozone Monitor

    Water quality monitoring and controlling ozone treatment systems
    Find out more
    Thiết bị giám sát quy trình rửa ngược FilterSmart

    FilterSmart Gravity Filter Backwash Monitor

    Allows water managers to monitor the backwashing process by measuring filter media level and turbidity with a single sensor
    Find out more
    Máy đo Ammonia hòa tan trong nước Q46N

    Q46N Dissolved Ammonia Monitor

    Real-time monitoring of Free and Total Ammonia for a variety of applications
    Find out more
    Máy đo độ dẫn điện Q46C4 4E

    Q46C4 4E Conductivity Monitor

    The solution for almost any water-based process monitoring
    Find out more
    Bộ truyền dẫn Clo dư Q45H/62-63

    Q45H/62-63 Residual Chlorine Transmitter

    Designed for on-line water quality monitoring and control of chlorination systems
    Find out more
    Thiết bị tách khí Clo tổng Q46H/79S

    Q46H/79S Total Chlorine Air Stripping Unit

    A gas-phase, non contacting approach to Total Chlorine monitoring, eliminating the potential for sensor fouling
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!