F12iS Toxic Gas Transmitter

Detection of gas leaks in explosion-hazard environments, while operating at intrinsically safe power levels

9 ₫

Key benefits

  • Intrinsically safe
  • Perfect choice for explosion-hazard environments
  • 60 different interchangable smart sensors
  • AutoTest sensor verification*
  • Heated sensor option

Applications

  • Wastewater treatment plants
  • Chemical plants
  • Pharmaceutical and medical
  • Semiconductor fabrication
  • Food processing
  • Mineral processing
  • Gas processing
  • Petroleum refining
Category:

ATi’s F12iS Toxic Gas Detector is designed to measure toxic gases and oxygen in hazardous locations requiring an Intrinsically Safe (IS) device. While operating at intrinsically-safe power levels, the F12iS is also available with our exclusive Auto-Test* feature that verifies sensor function daily, virtually eliminating the need for manual bump-tests.

For many toxic gases, ATi offers a unique sensor response testing system unmatched by any competitive gas transmitter. Even outdoors in high wind conditions, the Auto-Test system provides reliable response checks to ensure system integrity. Sensor response is verified with an actual gas sample that is generated on demand. Generators store run time information accessible to operators, and are automatically tested for compatibility with the installed electrochemical sensors.

F12 gas detectors provide useful features that simplify installation, operation, and maintenance. The 4-button keypad is used to configure the menu-driven setup pages. The display also provides alarm indication and complete menus for setting up operating parameters.

The F12/D, a non-iS version, is also available for non-hazardous locations.

*Dependent upon gas being monitored

Smart sensors

The F12iS uses ATi smart sensors that allow easy interchangeability. Each sensor contains signal conditioning electronics and data memory. Sensors can be calibrated using a spare unit avoid using calibration gases in the plant. Sensors may also be returned to ATi for factory calibration, which is useful for gases that are costly or difficult to obtain. Each sensor adjustment (zero or span) is stored in sensor memory and can be reviewed on the F12iS display. This data is very useful in assessing the sensor’s condition and estimating remaining sensor life.

Features & specification

  • Interchangeable sensors accommodating 60 different gas modules
  • Sensor verification with Auto-Test function
  • Test history is stored in sensor memory
  • LCD Graphic Display
  • Heated sensor option allows operation in high humidity
  • Remote sensor junction box with digital output allows sensor location up to 500 ft. from the F12iS
  • Internal data logger stores gas values at user defined intervals from 1 to 60 minutes
  • Calibration history and calibration adjustments of zero and span are stored in sensor memory
  • F12iS is available with optional Hart® output
  • CE and RoHS Compliant
Sensor Type Electrochemical cell
Gas Type Select sensor from listing on page 3
Range User adjustable within limits of selected sensor
Response Time Sensor dependent
Accuracy Generally ±5-10% of value, limited by available calibration gas accuracy
Repeatability ±1% (Electronic)
Linearity ±0.5% (Electronic)
Zero Drift Less than 2% full scale per month, non-cumulative
Span Drift Dependent on sensor environment but generally less than 3% per month
Analog Output 4-20 mA, 600 ohms max. at 24 VDC
Serial Interface (Optional) HART® digital signaling over the 4-20mA current loop
Power Requirements 12-28 VDC, 25 mA Maximum
75 mA Maximum with heated sensor
Enclosure IP 65, polycarbonate with stainless steel hardware.
Weatherproof and corrosion resistant. Refer to F12iS Support Drawings for Dimensions.
CE Mark 2014/35/EU – Low voltage directive
2014/30/EU – Electromagnetic compatibility
Certifications UL/CSA: I.S. for Class I, II, and III, Division 1 Locations
ATEX: Ex II 1 G Ex ia IIC T4 Ga,
-30°C ≤ Ta ≤ +60°C; IP65
IEC: Ex ia IIC T4 Ga, -30°C ≤ Ta ≤ +60°C
Mounting (Standard) Wall or pipe mount bracket. U-Bolts suitable for 1.5” or 2” I.D.
(Optional) Panel mount kit available
Auto-Test Option Dependent on sensor gas type and full scale range
Display 96×32 Dot-matrix Graphic LCD, Backlit, Transflective
Controls Four, dome-type push buttons; Remote alarm reset input (optional alarm relays only)
Temperature -30°C to +60°C (Min. temp. for O₂ Sensor is -20°C)
Environment 10 to 95% RH (non-condensing)
Weight 1.5 lb (0.68 kg)

F12iS Toxic Gas Transmitter

Download

Product reviews

Review F12iS Toxic Gas Transmitter

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review F12iS Toxic Gas Transmitter

There are no reviews yet.

No comments yet

Related products

icListen AF ALTA

icListen AF

Smart Digital Hydrophone – Frequency Range 10 Hz to 12 kHz
Find out more
Hydrophone kỹ thuật số thông minh icListen HF

icListen HF Hydrophone

10 Hz – 200 kHz
Find out more
Cảm biến giám sát khí thải xe ô tô

Remote sensing device (RSD)

Advanced vehicle emission monitoring technology
Find out more
Bộ ghi dữ liệu áp suất tức thời PIPEMINDER-ONE External

PIPEMINDER-ONE External Transient Pressure Data Logger

Suitable for wastewater, enables asset monitoring, pump performance alerts and more
Find out more
Bộ ghi dữ liệu áp suất PIPEMINDER-ONE Standard

PIPEMINDER-ONE Standard Pressure Transient Data Logger

High-resolution pressure data recording provides instantaneous and burst pressure detection
Find out more
Bộ ghi dữ liệu cảm biến âm thanh PIPEMINDER-ONE

PIPEMINDER-ONE Acoustic Sensor Data Logger

Combines acoustic and pressure monitoring for precise leak
Find out more
Máy nén khí cho đầu dò và cảm biến quang phổ

Air Compressor for Spectrometer Probes and Sensors

Provides compressed air for oxilyser, solilyser, ammolyser and spectrometer probes
Find out more
Thiết bị đo clo di động ChlorNet

ChlorNet Portable Chlorine Monitor

Provides mobile, accurate, reliable and real-time chlorine data
Find out more