When power is supplied to the CS231 probe, the internal electronics continuously measure the temperature at an approximate rate of one measurement per second. Every output measurement obtained from the sensor is a running average of 10 consecutive one-second readings. The accuracy specification is based on an average of 10 consecutive readings. For this reason, after the initial power up, it is recommended to delay 10 seconds to obtain the best accuracy.
Because the sensor is obtaining a measurement every one second, it is recommended to use the Continuous measurement command to obtain the temperature readings. Using the “R” commands will reduce the time taken to obtain a reading with the SDI-12 protocol.
Benefits and Features
-
- Lifetime min/max temperature recording
- User-resettable min/max temperature recording
- Automatic one-second temperature update
Review CS231-L SDI-12 Temperature Profiler