ClimaVue 50 Compact Digital Weather Sensor

Low power, compact, and simple for easy installation in remote locations

The ClimaVue™50 is an affordable all-in-one meteorological sensor that fulfills your common weather monitoring needs with simplicity, when paired with any of Campbell Scientific’s highly flexible and scalable data collection platforms. This sensor uses SDI-12 to report air temperature, relative humidity, vapor pressure, baro­metric pressure, wind (speed, gust, and direction), solar radiation, precipitation, and lightning strike (count and distance). It does this with no moving parts, while consuming little power. A built-in tilt sensor assures long-term data integrity. This diverse product is great for quick deployment, for remote locations, for large networks, as part of a more complex system, or if you just need something simple. 

Category:

Benefits and Features 

    • All the common meteorological measurements with one simple digital (SDI-12) output 
    • Less than 1 mA at 12 Vdc average current, making it ideal for solar-powered sites 
    • Integrated tilt sensor helps assure that the sensor stays level over time 
    • Low maintenance—no moving parts significantly reduces maintenance cost and time 
    • 304 stainless-steel hardware for minimal surface staining in marine environments 
    • No sensor configuration required 
    • Compact design for quick, low-impact installation 
    • Compatible with all modern Campbell Scientific data loggers 
    • Detachable cable facilitates field replacement 

Sensors 

All sensors are integrated into a single, small form-factor unit, requiring minimal installation effort. With a robust, no-moving-parts design that prevents errors because of wear or fouling, the ClimaVue 50 is ideal for long-term, remote installations. 

Pyranometer 

Solar radiation is measured by a pyranometer that is integrated into the lip of the rain gage funnel at the top of the ClimaVue 50. The miniature pyranometer uses a silicon-cell sensor to measure the total incoming (direct and diffuse) solar radiation. Silicon-cell sensors have excellent response time to changing radiation conditions and acceptable sensitivity across the solar spectrum, which make them well-suited for use on the ClimaVue 50. 

A carefully developed cosine-correcting head ensures accurate readings regardless of sun angle, while the painstakingly researched optical filter material balances cost and performance to ensure the silicon-cell provides the ClimaVue 50 with good accuracy regardless of temperature or sensor age.  

Anemometer 

The space underneath the rain gage is where the ClimaVue 50 measures wind speed. Ultrasonic signals emitted from transducers at right angles to each other bounce off the porous sintered glass plate and back up to the opposite sensor. The speed of sound is affected by the wind, and the wind speed is calculated by measuring differences in the time it takes for sound to travel from the transmitters to the receivers. 

Temperature Sensor 

The ClimaVue 50 temperature measurement is made in the center of the anemometer area where a small stainless-steel needle containing a tiny temperature sensor (thermistor) extends from the middle of the four sonic transducers in the center of the anemometer. 

Unlike most air temperature measurements, the temperature sensor is not covered with louvered plates to protect it from solar heating. Instead, it sits in open air, susceptible to solar heating of the instrument body. However, the ClimaVue 50 accurately corrects the measured air temperature because solar radiation and the wind speed are known. These two are the main variables that determine the error between measured air temperature and the actual air temperature. An energy balance equation is then used to calculate what the actual temperature should be to an accuracy of ±0.6°C.  

Relative Humidity Sensor 

The relative humidity sensor on the ClimaVue 50 is located behind the circular Teflon™ screen close to the sonic transducers. The Teflon screen protects the sensor from liquid water and dust while allowing water vapor to freely pass to the sensor. The ClimaVue 50 measures relative humidity and temperature and computes vapor pressure. 

Drip Counter Rain Gage 

The ClimaVue 50 contains a 9.31 cm (3.67 in.) diameter rain-collection funnel. A spring in the funnel acts as a filter to keep out large particles while allowing enough flow so water does not back up. Rain collected by the funnel exits the funnel through a precision flared hole that forms the rain into drops of a known size. The falling drops hit and momentarily bridge the gap between two gold pins, creating an electrical pulse.   

The ClimaVue 50 counts the pulses (drops) and calculates the water volume. As the rain intensity increases, the drops become smaller, but the ClimaVue 50 firmware contains an algorithm to automatically compensate for drop size as the rain increases. 

Note: This non-heated sensor is not suitable for solid precipitation measurements or riming environments. 

Tilt Sensor 

The ClimaVue 50 is also equipped with a tilt sensor. The primary use of the tilt sensor data is to ensure the ClimaVue 50 remains level at all times. Regularly check X and Y tilt data to ensure the ClimaVue 50 is level; if it has tilted, return to the site and level again. Three degrees off level can cause errors in the rain and solar radiation measurements. Although this sensor’s readings may be used to level the instrument during installation, it is much easier to use the small bubble level on the bottom of the anemometer plate. 

Mounting 

The ClimaVue 50 includes a V-bolt for mounting to a pipe with a nominal outer diameter of 31.8 to 50.8 mm (1.25 to 2.0 in.). This allows the sensor to mount directly to a tripod mast or CM300-series mounting pole, or to a crossarm using the 17387 mounting pipe kit. 

Measurements Made Air temperature, barometric pressure, lightning average distance, lightning strike count, precipitation, relative humidity, solar radiation, tilt, wind direction, and wind speed.
Output SDI-12
Operating Temperature Range -50° to +60°C (Except the barometer and RH: -40° to +60°C.)
Minimum Supply Voltage 3.6 Vdc continuous
Maximum Supply Voltage 15.0 Vdc continuous
Minimum Digital Input Voltage
  • 2.8 V (logic high)
  • -0.3 V (logic low)
Typical Digital Input Voltage
  • 3.0 V (logic high)
  • 0.0 V (logic low)
Maximum Digital Input Voltage
  • 5.5 V (logic high)
  • 0.8 V (logic low)
Typical Current Drain @ 12 Vdc < 1 mA (average)
Typical Measurement Duration 110 ms
Maximum Measurement Duration 3,000 ms
Maximum Polling Frequency 10 s
Application of Council Directive(s)
  • 2011/65/EU: Restrictions of Substances Directive (RoHS2)
  • 2014/30/EU: Electromagnetic Compatibility Directive (EMC)
Standards to Which Conformity Is Declared
  • EN 61326-1:2013: Electrical equipment for measurement, control and laboratory use—EMC requirements—for use in industrial locations
  • EN 50581:2012: Technical documentation for the assessment of electrical and electronic product with respect to the restriction of hazardous substances
Connection Description 25 mm (10 in.) pigtail with M12 pin (male) 5-pin 316 stainless-steel knurl
Diameter 10 cm (4 in.) including rain gage funnel
Height 34 cm (13.4 in.) including rain gage funnel
Weight 839.15 g (1.85 lb)
Power Consumption
Quiescent 0.3 mA
Maximum Peak Current 33 mA
Average Using the R7! Command every 10 s 1.0 mA
Average Using the R7! Command every 60 s (or slower) 0.4 mA
Air Temperature
Measurement Range -50° to +60°C
Resolution 0.1°C
Accuracy ±0.6°C
Relative Humidity
Measurement Range 0 to 100%
Resolution 0.1
Accuracy ±3% RH typical (varies with temperature and humidity)
Barometric Pressure
Barometer Operating Temperature Range -40° to +60°C
Measurement Range 500 to 1100 hPa
Resolution 0.1 hPa
Accuracy
  • ±1 mb (over the range of -10° to +50°C)
  • ±5 mb (over the range of -40° to +60°C)
Vapor Pressure
Measurement Range 0 to 47 kPa
Resolution 0.01 kPa
Accuracy or Repeatability Varies with temperature and humidity; ±0.2 kPa typical below 40°C.
Wind Speed
Wind Speed Maximum 10 s gust
Measurement Range 0 to 30 m/s (0 to 67 mph)
Resolution 0.01 m/s (0.02 mph)
Accuracy or Repeatability 0.3 m/s or 3% (0.67 mph or 3%), whichever is greater
Wind Direction
Measurement Range 0° to 359°
Resolution
Accuracy ±5°
Solar Radiation
Measurement Range 0 to 1750 W m-2
Resolution 1 W m-2
Accuracy ±5% of measurement (typical)
Spectral Range 300 to 1150 nm
Precipitation
Measurement Range 0 to 400 mm/h (15.75 in./h)
Resolution 0.017 mm
Accuracy ±5% of measurement (from 0 to 50 mm/h or 0 to 1.97 in./h)
Tilt
Measurement Range -90° to +90°
Resolution 0.1°
Accuracy ±1°
Lightning Strike Count
Measurement Range 0 to 65,535 strikes
Resolution 1 strike
Accuracy > 25% detection at < 10 km typical (variable with distance)
Lightning Average Distance
Measurement Range 0 to 40 km (0 to 24.9 mi)
Resolution 3 km (1.86 mi)
Accuracy Variable

Brochures: ClimaVue™50 Compact Digital Weather Sensor

Download

Manuals: ClimaVUE™50 Compact Digital Weather Sensor

Download

Product reviews

Review ClimaVue 50 Compact Digital Weather Sensor

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review ClimaVue 50 Compact Digital Weather Sensor
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Skyspec instruments

    Passive remote sensing of atmospheric particles and gases
    Find out more
    OPEN PATH

    Open-path active remote sensing instrument

    Fast and accurate spectral trace gas measurements using active spectroscopy
    Find out more
    Hệ thống phân tích NO2-NOx-NO ICAD Series 210DL

    ICAD NO2-NOx-NO Analyzer SERIES 210DL

    Patented, fast, accurate and direct nitrogen dioxide detection
    Find out more
    Hệ thống phân tích ICAD-HONO/NO2-200L

    Icad HONO-NO2 Analyzer series 210

    Patented, fast, accurate and direct hono and no2 detection
    Find out more
    Bộ thu thập và xử lý dữ liệu Granite 10

    Granite 10 Measurement and Control Data-Acquisition System

    Ideal for automotive testing applications, featuring CAN bus and CAN FD output
    Find out more
    Mô-đun Đầu vào Cổng Dòng điện 100 Ohm CURS100

    CURS100 100-Ohm Current Terminal Input Module

    Expands capabilities, allows data logger to measure additional types of sensors
    Find out more
    Datalogger ba kênh cho cảm biến dây rung CRVW3-NE

    CRVW3-NE Three-Channel Vibrating Wire Datalogger without Enclosure

    Vibrating Wire Data Logger Using patented VSPECT™ technology
    Find out more
    Bộ Ghi Dữ Liệu Dây Rung Ba Kênh CRVW3

    CRVW3 Three-Channel Vibrating Wire Datalogger

    Self-Contained Vibrating Wire Data Logger Using patented VSPECT® technology
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!