PTB210 Digital Barometer

for harsh environments

Model: PTB210
Manufacturer: Vaisala – Finland

Excellent solution for outdoor installations. Operates in a wide temperature range. The housing provides IP65 (NEMA4) compliant protection against sprayed water.

Features

  • 500 … 1100 hPa or 50 …. 1100 hPa pressure ranges with serial output
  • Different scalings between 500 … 1100 hPa with analog output
  • Electronics housing IP65 protected against sprayed water
  • Accurate and stable measurement
  • NIST traceable (certificate included)
Category:

 For harsh environments

The Vaisala BAROCAP® Digital Barometer PTB210 is ideal for outdoor installations and harsh environments. The barometers are designed to operate in a wide temperature range, and the electronics housing provides IP65 (NEMA 4) standardized protection against sprayed water.

Excellent hysteresis and repeatability characteristics

The PTB210 barometers use the Vaisala BAROCAP® Sensor, a silicon capacitive absolute pressure sensor developed by Vaisala for barometric pressure applications. The Vaisala BAROCAP® Sensor provides also outstanding temperature and long-term stability

Several pressure ranges

The PTB210 barometers are designed for various pressure ranges. They are available in two basic configurations: serial output for 500 … 1100 hPa and 50 … 1100 hPa and analog output with different scalings between 500 … 1100 hPa.

Vaisala BAROCAP technology

PTB210 uses the Vaisala BAROCAP sensor, a silicon capacitive absolute pressure sensor developed by Vaisala for barometric pressure applications.The Vaisala BAROCAP sensor provides excellent hysteresis and repeatability characteristics and outstanding temperature and long-term stability. PTB210 is delivered with a traceable factory calibration certificate.

Measurement performance

Pressure range

Serial output 500 … 1100 hPa 

50 … 1100 hPa

Analog output 500 … 1100 hPa 

600 … 1060 hPa 

800 … 1060 hPa 

900 … 1100 hPa

 

Serial output, accuracy (hPa)
Pressure range 500 … 1100 50 … 1100

 

Class A Class B
Non-linearity 1)  ± 0.10 ± 0.15 ± 0.20
Hysteresis 1) ± 0.05 ± 0.05 ± 0.10
Repeatability 1) ± 0.05 ± 0.05 ± 0.10
Calibration uncertainty 2) ± 0.07 ± 0.15 ± 0.20
Accuracy at +20 °C (+68 °F) 3) ± 0.15 ± 0.20 ± 0.35
Temperature dependency 4) ± 0.20 ± 0.20 ± 0.40
Total accuracy -40 … +60 °C (-40 … +140 °F) 3)  ± 0.25 ± 0.30 ± 0.50
Long-term stability (hPa/ year) ± 0.10 ± 0.10 ± 0.20

 

Analog output, accuracy

 

Non-linearity 1) ± 0.20 hPa
Hysteresis 1) ± 0.05 hPa
Repeatability 1) ± 0.05 hPa
Calibration uncertainty 2) ± 0.15 hPa
Accuracy at +20 °C (+68 °F) 3) ± 0.30 hPa
Temperature dependency 4) ± 0.50 hPa
Total accuracy -40 … +60 °C (-40 … +140 °F) 3) ± 0.60 hPa
Long-term stability ± 0.10 hPa/year

 

1) Defined as the ±2 standard deviation limits of end point non-linearity, hysteresis error, or repeatability error. 

2) Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to international standards. 

3) Defined as the root sum of the squares (RSS) of end point non-linearity, hysteresis error, repeatability error, and calibration uncertainty at room temperature. 

4) Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. 

 

Operating environment

 

Operating temperature −40 … +60 °C (−40 … +140 °F)
Operating humidity 0 … 100 %RH, non‑condensing

 

Compliance

 

Directives EMC Directive (2014/30/EU) RoHS Directive (2011/65/EU)
EMC compatibility EN / IEC 61326-1, Electrical equipment for measurement, control and laboratory use – EMC requirement; Basic environment CISPR 32 / EN 55032, Class B
Compliance  CE, FCC, UKCA 

 

Mechanical specifications

 

Housing material PC plastic
IP rating, electronics IP65 (NEMA 4)
IP rating, sensor IP53
Weight, sensor 110 g (3.9 oz)
Cable weight 28 g/m (1.0 oz)

 

Inputs and outputs 

 

Serial output
Shutdown ON/OFF 
Settling time at startup 2 s
Serial I/O RS-232C 

RS-232C / TTL (optional) 

RS-485, non-isolated (optional)

Parity None, even, odd
Data bits 7, 8
Stop bits 1, 2
Baud rate 1200, 2400, 4800, 9600, 19200
Response time 1 s
Resolution 0.01 hPa (1 measurement/s) 

0.03 hPa (10 measurements/s)

Current consumption, normal mode < 15 mA (factory setting)
Current consumption, shutdown mode 0.2 mA
Analog output
Outputs 0 … 5 V DC, 0 … 2.5 V DC 

(order specified)

Shutdown ON/OFF
Response time 500 ms
Resolution 300 μV
Measurement rate 3 measurements/s
Current consumption, normal mode < 8 mA
Current consumption, shutdown mode 0.2 mA
All models
Max. pressure 5 000 hPa absolute
Pressure connector M5 (10-32) internal thread
Pressure fitting Barbed fitting for 1/8 in I.D. tubing
Supply voltage (reverse polarity protected), with RS-232/TTL output 5 … 28 V DC
Supply voltage (reverse polarity protected), with RS-485 or analog output 8 … 18 V DC

 

BAROCAP® Digital Barometer PTB210 Datasheet

Download

Product reviews

Review PTB210 Digital Barometer

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review PTB210 Digital Barometer
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Bộ ghi dữ liệu áp suất tức thời PIPEMINDER-ONE External

    PIPEMINDER-ONE External Transient Pressure Data Logger

    Suitable for wastewater, enables asset monitoring, pump performance alerts and more
    Find out more
    Bộ ghi dữ liệu áp suất PIPEMINDER-ONE Standard

    PIPEMINDER-ONE Standard Pressure Transient Data Logger

    High-resolution pressure data recording provides instantaneous and burst pressure detection
    Find out more
    Bộ ghi dữ liệu cảm biến âm thanh PIPEMINDER-ONE

    PIPEMINDER-ONE Acoustic Sensor Data Logger

    Combines acoustic and pressure monitoring for precise leak
    Find out more
    Máy nén khí cho đầu dò và cảm biến quang phổ

    Air Compressor for Spectrometer Probes and Sensors

    Provides compressed air for oxilyser, solilyser, ammolyser and spectrometer probes
    Find out more
    Thiết bị đo clo di động ChlorNet

    ChlorNet Portable Chlorine Monitor

    Provides mobile, accurate, reliable and real-time chlorine data
    Find out more
    Thiết bị đo khí Chlorine Dioxide Q45H/65

    Q45H/65 Chlorine Dioxide Transmitter

    Online water quality monitoring and control of industrial disinfection systems
    Find out more
    Thiết bị đo ozone hòa tan Q45H/64

    Q45H/64 Dissolved Ozone Transmitter

    Online water quality monitoring and control of ozonation system
    Find out more
    Thiết bị đo độ dẫn điện kiểu Toroidal Q45CT

    Q45CT Toroidal Conductivity Transmitter

    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!