Heavy volatile hydrocarbon analysis system AirmoVOC C6-C12

Phân tích lên đến 53 hợp chất trong khoảng C6 đến C12, phù hợp cho quan trắc môi trường, giám sát khí thải công nghiệp và kiểm soát chất lượng không khí

The AirmoVOC C6-C12 is an advanced analyzer designed for the measurement of volatile hydrocarbon compounds, including BTEX (Benzene, Toluene, Ethylbenzene, and Xylene) as well as halogenated compounds (TO14). This device can analyze up to 53 compounds within the C6-C12 range, making it ideal for environmental monitoring, industrial emissions surveillance, and air quality control.

Applications

Environmental Monitoring:

  • Air pollution control in urban and non-urban areas.
  • Indoor air quality measurement.
  • BTEX, PAMS, and Volatile Organic Compounds (VOC) analysis.

Industrial Emission Surveillance:

  • Pollution control from factories and industrial zones.
  • Fence line monitoring to track emissions at facility boundaries.

Other Applications:

  • Ambient air monitoring around wastewater treatment plants.
  • VOC analysis in water using the Purge and Trap method (502-2 or 524).
  • Air quality surveillance following PAMS and TO14 methods.
Category:

The AirmoVOC C6-C12 is designed with high sensitivity, compact size, mobility, and flexibility, making it widely applicable for urban and non-urban pollution control, indoor air quality measurement, industrial process monitoring, and emissions surveillance. The entire system, from the sampling port to data storage, is integrated into a compact 19’’-rack 5U unit.

Operating Principle

The AirmoVOC C6-C12 operates using a 6-port valve system combined with a single sorbent trap and a metallic capillary column, installed in a programmable temperature gradient oven. The device utilizes a Flame Ionization Detector (FID) to ensure high accuracy in detecting volatile organic compounds (VOCs). The carrier gas is controlled by a piezo valve, allowing for precise pressure and flow regulation.

Key Features

  • Analytical Capability: Up to 53 compounds in the C6-C12 range, including BTEX, PAMS, and halogenated compounds (TO14).
  • Measurement Cycle: 30 minutes (optional 60 minutes available).
  • Sampling Method: Vacuum pump, with sample volume ranging from 30 to 700 ml (programmable, sampling time up to 40 minutes).

Integrated Vistachrom Software

The device is equipped with Vistachrom software, allowing users to:

  • Visualize and store data on a PC.
  • Perform recalculations, calibrations, and data exports.
  • Set up measurement parameters.
  • Calculate retention time, area, mass, and compound concentration profiles.

Optional Enhancements

  • Online data transmission via MODBUS / JBUS or MGS1 communication protocols.
  • AirmoVOC Expert: Detection limit of 1 ppt.
  • Automatic validation and calibration with internal CALIB system.
  • 24V power supply, suitable for portable analyzers.
  • Hydrogen and zero-air generator to support transportable analyzers.
  • Multiplexer support for 2 to 32 sampling points.
  • Purge module for VOC extraction from water, enabling online VOC-in-water analysis.
  • Internal or external multi-point calibration and zeroing with options such as CALIB MFC, XXXCYL MFC, airmoCAL MFC, or airmoCAL D.
  • Extended analysis range up to C16 with the airmoVOC C6-C16 model.

Certifications & Quality Control

  • MCERTS certification for benzene measurement, compliant with EN 14662-3 standards.
  • Rigorous quality control testing before delivery (minimum 1-week testing period in the Quality Control department).

Detection Limit
  • Tri-methylbenzene : 10 ppt or 0.05 µg/m3
  • Benzene : 10 ppt in standard,
  • 1 ppt with airmoVOC Expert
Detection Range
  • 0.05 to 45 µg/m3 for Tri-methylbenzene  and Benzene (amplification 3)
  • 0.5 to 400 µg/m3 for Tri-methylbenzene  and Benzene (amplification 2)
Relative Standard Deviation
  • < 0.3 %over 48h (RT)
  • < 3 % over 48 h (Conc.)
Results
  • Data storage
  • 4-20mA current output (option)
  • MODBUS / JBUS or MGS1 communication protocol (option)
Cycle time 30 min as standard (60 min optional)
Gas supply
  • H2 (FID and carrier gas): 30 ml/min
  • Air (FID): 180 ml/min
  • Sample inlet (vacuum pump)
Sample volume 30 to 700 ml (programmable) in standard (sampling time up to 40 minutes)

TSP airmoVOC C6-C12

Download

Product reviews

Review Heavy volatile hydrocarbon analysis system AirmoVOC C6-C12

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Heavy volatile hydrocarbon analysis system AirmoVOC C6-C12
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    airmoMEDOR

    AirmoMEDOR automated gas chromatography device for analyzing and monitoring odorous sulfur compounds

    Quantification of trace amounts of odorous sulfur compounds at ppm, ppb, and ppt levels
    Find out more
    chromaS

    Automated Sulfur Compounds Analyzer – Chroma S

    Automated online analysis & monitoring of sulfur compounds: H₂S / COS / CS₂ / SO₂ / RSH
    Find out more
    Auto GCMS C10C40

    Auto GC‑MS C10C40

    Portable Ultra‑Compact GC‑MS/FID Trap System
    Find out more
    MicroVOC

    Mobile VOC Analyzer – microVOC/microBTEX

    Real-time identification and quantification of volatile organic compounds (VOCs) with high precision
    Find out more
    Hệ thống giám sát Ozone airmOzone

    airmOzone Ozone Monitoring System

    A Comprehensive Solution for Monitoring Ozone Precursors (PAMS 56) and Toxics
    Find out more
    Thiết bị phân tích hợp chất hữu cơ airmoVOC C6-C20

    AirmoVOC C6-C20 Organic Compound Analyzer

    Measurement of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) in ambient air.
    Find out more
    chromaPID

    BTEX Analyzer Using ChromaPID PID Sensor

    Analyzes and monitors volatile organic compounds (VOCs) and other related substances in air, water, or soil
    Find out more
    ChromaFID

    ChromaFID Volatile Organic Compound (VOC) Analysis System

    GC/FID for Automatic, Continuous Analysis of VOCs (from 20 ppb to ppm)
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!