HAL 101X RC

Residual Gas Analyser developed for Tokamaks, and harsh operating environments

  • Model: HAL 101X RC
  • Manufacturer: Hiden Analytical

Hiden RGA series systems are designed for residual gas analysis, gas analysis and process monitoring applications including leak detection, trend analysis and vacuum survey. The HAL 101X RC is a specific analyser with additional features for real time quantitative analysis of complex gas and vapour mixtures in fusion applications and harsh operating environments.

Applications

  • Fusion research
  • Residual gas analysis
  • Leak detection
  • Desorption
  • Outgassing studies
  • Bakeout cycles
  • Pump performance
  • Process gas contaminants
Category:

Hiden RGA series systems are designed for residual gas analysis, gas analysis and process monitoring applications including leak detection, trend analysis and vacuum survey.

 

The HAL 101X RC is a specific analyser with additional features for real time quantitative analysis of complex gas and vapour mixtures in fusion applications and harsh operating environments.

The quadrupole analyser is a precision assembly including a mass filter with machined radial ceramic supports plus; an electron impact ioniser with twin oxide coated iridium filaments and dual Faraday / Channeltron electron multiplier detectors. The analyser mounting flange is a DN-35-CF (2¾”, 70 mm OD) Conflat type flange. Mass range for the HAL 101X RC is 100 amu. Other mass ranges available on request.

The HAL 101X RC mass spectrometer is directly controlled from a PC compatible computer via USB or Ethernet TCP/IP link, providing simultaneous data acquisition from multiple systems. The RC interface unit is a 90 mm high (2U), 19-inch rack mounting unit.  It is mains powered and includes power on and filament status indicators.

The HAL 101X RC system includes a transformer coupled matching unit and adaptor for remote mounting the systems sensitive electronics including the preamplifier/ RF unit at up to 140 m from the analyser gauge.

Windows®-MASsoft PC software provides for fast data acquisition through either user configured acquisition files or pre-set modes selected by icon.

Features

  • Fastaccess for Histogram, Trend Analysis and Analogue peak 
  • Templatefiles for complex hydrocarbon and deuterated hydrocarbon analy
  • QuantitativeHe/D2 analy
  • Simultaneousreal time display of graphical and tabular trend analysis dat
  • Dataacquisition from multiple systems via Ethernet.
  • Automaticmass scale alignment.
  • Integralmass spectral library with full editing facilit

Operation of the quadrupole analyser at distances of up to 140 m from the sensitive electronics.

Mass Range: 100 amu
Maximum Operating Pressure : 1 x 10-4 mbar with Faraday detector.
Resolution: 10% Valley between adjacent peaks of equal height throughout the mas range. Software adjustable.
Detector: Twin detector: Faraday cup and electron multiplier detector. 
Min detectable partial pressure: 2 x 10-12 mbar with 80 m cable set.

The minimum detectable partial pressure is cable length dependant.

The figure quoted is for the instrument using an 80 m cable set. A shorter cable length will result in a lower minimum detectable partial pressure limit.

The limit of detection as a function of cable length is approximately as follows:

1.6 x 10-13 + (N x 2 x 10-14) mbar, where N is the cable length in metres.

Measurement speed
Maximum measurement speed: 650 measurements per second.
Ion Source: Radially symmetric, UHV compatible ion source.
Filament: Twin filament.

Oxide coated iridium is standard.

Ion Source control
Electron emission: Software variable 1 µA to 2 mA.
Electron energy: Software variable 0 to 150 eV
Ion energy: Software variable 0 to 10 eV 
PC Software: MASsoft
Communications to PC: RS232, USB 2.0, 10/100 Base-T LAN
RC interface unit I/O: 5 configurable I/O TTL lines, 2 analog inputs, 2 trip relay outputs, external trip input and over-pressure trip output.

3 RS485 (multi-protocol) to interface with a wide range of external devices, MFCs for example.

8 digital inputs compatible with 5 V and 24 V logic levels. 8 open collector digital outputs (30 V, 500 mA max).

4 or 8 channel analog outputs, 0-10 V, 14 bit (optional).

Power   requirement 100-240 V AC, 50-60 Hz, 250 VA.

Mass Spectrometers for Residual Gas Analysis – RGA | For Applications in a Vacuum Environment

Download

Product reviews

Review HAL 101X RC

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review HAL 101X RC
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Hệ thống GC/PID tự động giám sát BTEX và 1,3-Butadiene airTOXIC BTX PID

    Automatic GC/PID System for BTEX and 1,3-Butadiene Monitoring – airTOXIC BTX PID

    The airTOXIC BTX PID is an automatic monitoring device that detects BTEX compounds (Benzene, Toluene, Ethylbenzene, Xylene) and 1,3-Butadiene in air, water, and soil
    Find out more
    Hệ thống GC/FID giám sát BTEX tự động airmoVOC BTX

    AirmoVOC BTX – Automatic GC/FID BTEX Monitoring System

    Analysis and Monitoring of Trace BTEX Compounds in Air, Water, and Soil
    Find out more
    Hệ thống phân tích Hydrocacbon bay hơi nặng AirmoVOC C6-C12

    Heavy volatile hydrocarbon analysis system AirmoVOC C6-C12

    Phân tích lên đến 53 hợp chất trong khoảng C6 đến C12, phù hợp cho quan trắc môi trường, giám sát khí thải công nghiệp và kiểm soát chất lượng không khí
    Find out more
    airmoVOC 624

    Light Hydrocarbon and BTEX Analysis System – airmoVOC 624

    Analysis of up to 49 compounds using TO14 or PAMS methods
    Find out more
    airmoOVOC

    airmoOVOC – Light Oxygenated VOCs Analysis System

    Analysis of light oxygenated VOC’s in air or pure gas
    Find out more
    airmoF

    Automated Online Formaldehyde Analysis System – airmoF

    Continuous and Real-time Formaldehyde Monitoring in Various Environments
    Find out more
    airmoVOC C2-C6

    AirmoVOC C2-C6 Light Volatile Hydrocarbon Analyzer

    Measures light volatile hydrocarbon compounds in the range of C2 to C6
    Find out more
    energyMEDOR

    energyMEDOR

    Online Analysis and Monitoring of Sulfur Compounds in Natural Gas and Gaseous Fuels
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!