The CR310 is a multi-purpose, compact, low-cost measurement and control data logger that includes an integrated 10/100 Ethernet port and removable terminal connectors. This entry-level data logger, with its rich instruction set, can measure most hydrological, meteorological, environmental, and industrial sensors. It will concentrate data, making it available over varied networks and deliver it using your preferred protocol. The CR310 also performs automated on-site or remote decision making for control and M2M communications. The CR310 is ideal for small applications requiring long-term, remote monitoring and control.

The primary differences between the CR300 and CR310 are that the CR310 offers removable connectors and a 10/100 Ethernet connection.

Category:

Terminal Descriptions

  • One switched 12 V terminal (SW12V) for powering sensors or communication devices, 1100 mA @ 20°C
  • Two sensor excitation or continuous 0.15 to 5 V terminals (VX1, VX2) for sensor excitation or output control
  • Six multipurpose analog input terminals (SE1 – SE6)
    • Analog functions (SE1 – SE6)
      • Analog inputs: 6 single-ended or 3 differential inputs with -100 to +2500 mV and ±34 mV ranges 24 bit ADC
      • 4 to 20 mA or 0 to 20 mA inputs (SE1, SE2 only)
    • Digital I/O functions (SE1 – SE4) consist of 3.3 V logic levels for:
      • High frequency counter (35 kHz)
      • Pulse width modulation
      • Interrupts and timer input
      • Period average (200 kHz, amplitude dependent)
  • Two Pulse Counting Terminals (P_SW, P_LL)
    • P_SW
      • Switch closure (150 Hz)
      • High frequency counter (35 kHz)
    • P_LL
      • Low level ac (20 kHz)
      • High frequency counter (20 kHz)
  • Two Control Terminals (C1, C2): C terminals are software configurable for digital functions
    • Digital I/O functions consist of 5 V output and 3.3 V input logic levels for:
      • SDI-12
      • High frequency counter (3 kHz)
      • Switch closure (150 Hz)
      • General status/control
      • Voltage source 5 V: 10 mA @ 3.5 V
      • Interrupts
      • Serial asynchronous communication Tx/Rx pair

Benefits and Features

    • Set up easily with PC software and USB connectivity
    • Measure with confidence analog and digital sensors
    • Internet ready–email, FTP, HTTP/web, TCP–with required add-ons
    • Trust in the Campbell Scientific quality, including integral surge and ESD protection
    • Save money and space using the integrated Ethernet port
    • Network wirelessly to another node or Internet gateway with integrated radio option
    • CR310-WIFI ideal for short-range, wireless IP communication
    • Wiring made easy through removable terminal block
    • Communicate from anywhere when using cellular or satellite peripheral
    • Charge batteries using the integrated 12 V battery solar charge regulator
    • Measure smart sensors using RS-232 or SDI-12
    • Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols
    • Analyze and control with programmability and multiple general purpose I/O
    • Notify with event-driven communications and physical outputs
-NOTE- Additional specifications are listed in the CR300-Series Specifications Sheet.
Operating Temperature Range
  • -40° to +70°C (standard)
  • Non-condensing environment
Maximum Scan Rate 10 Hz
Case Material Powder-coated aluminum
Analog Inputs 6 single-ended or 3 differential (individually configured)
Pulse Counters 8 (P_SW, P_LL, C1, C2, and SE1 to SE4)
Voltage Excitation Terminals 2 (VX1, VX2)
Communications Ports
  • USB Micro B
  • RS-232
  • 10/100 Ethernet RJ45
Switched 12 Volt 1 terminal
Digital I/O 7 terminals (C1, C2, P_SW, and SE1 to SE4) configurable for digital input and output. Includes status high/low, pulse width modulation, external interrupt, and communication functions. Exception: The SE4 terminal doesn’t do external interrupt.
Input Limits -100 to +2500 mV
Analog Voltage Accuracy
  • Accuracy specifications do not include sensor or measurement noise.
  • ±(0.04% of measurement + offset) at 0° to 40°C
  • ±(0.1% of measurement + offset) at -40° to +70°C
ADC 24-bit
Power Requirements 16 to 32 Vdc for charger input (CHG) (Current limited to 0.9 A maximum for power converter or solar panel input.)
Power Requirements 10 to 18 Vdc for external batteries (BAT)
Real-Time Clock Accuracy ±1 min. per month
Internet Protocols Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP(APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS
Communication Protocols PakBus, Modbus, DNP3, SDI-12, TCP, UDP, and others
CPU Drive/Programs 80 MB serial flash
Data Storage 30 MB serial flash
Idle Current Drain, Average 10 mA (@ 12 Vdc with Ethernet link idle)
Active Current Drain, Average 56 mA (@ 12 Vdc with Ethernet link active, processor always on)
Dimensions 16.26 x 7.62 x 5.68 cm (6.4 x 3.0 x 2.2 in.)
Weight 288 to 306 g (0.64 to 0.68 lb) depending on communication option selected
CR310-RF407 Option
Radio Type Frequency Hopping Spread Spectrum (FHSS)
Output Power 5 to 250 mW (user-selectable)
Frequency 902 to 928 MHz (US, Canada)
RF Data Rate 200 kbps
Receive Sensitivity -101 dBm
Antenna Connector RPSMA (external antenna required; see www.campbellsci.com/order/rf407 for Campbell Scientific antennas)
Idle Current Drain, Average 12 mA (@ 12 Vdc)
Active Current Drain, Average < 80 mA (@ 12 Vdc)
CR310-RF412 Option
Radio Type Frequency Hopping Spread Spectrum (FHSS)
Output Power 5 to 250 mW (user-selectable)
Frequency 915 to 928 MHz (Australia, New Zealand)
RF Data Rate 200 kbps
Receive Sensitivity -101 dBm
Antenna Connector RPSMA (external antenna required; see www.campbellsci.com/order/rf412 for Campbell Scientific antennas)
Idle Current Drain, Average 12 mA (@ 12 Vdc)
Active Current Drain, Average < 80 mA (@ 12 Vdc)
CR310-RF422 Option
Radio Type 868 MHz SRD 860 with Listen Before Talk (LBT) and Automatic Frequency Agility (AFA)
Output Power 2 to 25 mW (user-selectable)
Frequency 863 to 870 MHz (European Union)
RF Data Rate 10 kbps
Receive Sensitivity -106 dBm
Antenna Connector (External antenna required; see www.campbellsci.com/order/rf422 for Campbell Scientific antennas.)
Idle Current Drain, Average 9.5 mA
Active Current Drain, Average 20 mA
CR310-RF427 Option
Radio Type Frequency Hopping Spread Spectrum (FHSS)
Output Power 5 to 250 mW (user-selectable)
Frequency 902 to 907.5 MHz/915 to 928 MHz (Brazil)
RF Data Rate 200 kbps
Receive Sensitivity -101 dBm
Antenna Connector RPSMA (External antenna required.)
Idle Current Drain, Average 12 mA (@ 12 Vdc)
Active Current Drain, Average < 80 mA (@ 12 Vdc)
CR310-WIFI Option
Operational Modes Client or Access Point
Operating Frequency 2.4 GHz, 20 MHz bandwidth
Antenna Connector Reverse Polarity SMA (RPSMA)
Antenna pn 16005 unity gain (0 dBd), 1/2 wave whip, omnidirectional with articulating knuckle joint for vertical or horizontal orientation
Transmit Power 7 to 18 dBm (5 to 63 mW)
CR310-CELL205 Option
-NOTE- The CR310-CELL205 option is not compatible with a Verizon cellular network.
Cell Technologies
  • 3G (UMTS/HSPA+)
  • 4G (LTE CAT-1)
3G Frequency Bands 850, 1700/2100 (AWS), and 1900
4G Frequency Bands 700, 850, 1700/2100 (AWS-1), 1900
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr310 for Campbell Scientific antennas.)
SIM Interface 3FF (6 position/contacts)

Supports SIMs that require 1.8 or 3 V.

CR310-CELL210 Option
-NOTE- The CR310-CELL210 option is only compatible with a Verizon cellular network. CR310-CELL205 Option No
Cell Technologies 4G (LTE CAT-1)
4G Frequency Bands 700, 850, 1700, 1900, 2100
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr310 for Campbell Scientific antennas.)
SIM Interface 3FF (6 position/contacts)

Supports SIMs that require 1.8 or 3 V.

CR310-CELL215 Option
-NOTE- The CR310-CELL215 option is intended for use in EMEA countries.
Cell Technologies
  • 2G (GSM/GPRS/EDGE)
  • 3G (UMTS/HSPA+)
  • 4G (LTE CAT-1)
2G Frequency Bands 900 and 1800 MHz
3G Frequency Bands 850, 900, and 2100 MHz
4G Frequency Bands 800, 850, 900, 1800, 2100, and 2600 MHz
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr310 for Campbell Scientific antennas.)
SIM Interface 3FF (6 position/contacts)

Supports SIMs that require 1.8 or 3 V.

CR310-CELL220 Option
-NOTE- The CR310-CELL220 option is intended for use in Australia and New Zealand.
Cell Technologies
  • 3G (UMTS/HSPA+)
  • 4G (LTE CAT-1)
3G Frequency Bands
  • 850 and 2100 MHz (EC-21AUT)
  • 850, 900, 1900, and 2100 MHz (EC-21AU)
4G Frequency Bands
  • 700, 850, 1800, 2100, and 2600 MHz (EC-21AUT)
  • 700, 900, 1700, 1800, 1900, 2100, and 2600 MHz (EC-21AU)
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr310 for Campbell Scientific antennas.)
SIM Interface 3FF (6 position/contacts)

Supports SIMs that require 1.8 or 3 V.

CR310-CELL225 Option
-NOTE- The CR310-CELL225 option is intended for use in Japan.
Cell Technologies 4G (LTE CAT-1)
4G Frequency Bands 800 (lower), 800 (upper), 850+, 900, 1800, and 2100 MHz
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr310 for Campbell Scientific antennas.)
SIM Interface 3FF (6 position/contacts)

Supports SIMs that require 1.8 or 3 V.

Brochures: CR310 Datalogger with Ethernet

Download

Brochures: CR300-Series Specifications Sheet

Download

Brochures: Cellular Data Services

Download

Product reviews

Review CR310 Measurement and Control Datalogger

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review CR310 Measurement and Control Datalogger
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Skyspec instruments

    Passive remote sensing of atmospheric particles and gases
    Find out more
    OPEN PATH

    Open-path active remote sensing instrument

    Fast and accurate spectral trace gas measurements using active spectroscopy
    Find out more
    Hệ thống phân tích NO2-NOx-NO ICAD Series 210DL

    ICAD NO2-NOx-NO Analyzer SERIES 210DL

    Patented, fast, accurate and direct nitrogen dioxide detection
    Find out more
    Hệ thống phân tích ICAD-HONO/NO2-200L

    Icad HONO-NO2 Analyzer series 210

    Patented, fast, accurate and direct hono and no2 detection
    Find out more
    Bộ thu thập và xử lý dữ liệu Granite 10

    Granite 10 Measurement and Control Data-Acquisition System

    Ideal for automotive testing applications, featuring CAN bus and CAN FD output
    Find out more
    Mô-đun Đầu vào Cổng Dòng điện 100 Ohm CURS100

    CURS100 100-Ohm Current Terminal Input Module

    Expands capabilities, allows data logger to measure additional types of sensors
    Find out more
    Datalogger ba kênh cho cảm biến dây rung CRVW3-NE

    CRVW3-NE Three-Channel Vibrating Wire Datalogger without Enclosure

    Vibrating Wire Data Logger Using patented VSPECT™ technology
    Find out more
    Bộ Ghi Dữ Liệu Dây Rung Ba Kênh CRVW3

    CRVW3 Three-Channel Vibrating Wire Datalogger

    Self-Contained Vibrating Wire Data Logger Using patented VSPECT® technology
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!