CR300 Measurement and Control Datalogger

Compact data logger, ideal for small applications

The CR300 is a multi-purpose, compact measurement and control data logger. This small, low-cost, high-value data logger offers fast communications, low power requirements, built-in USB, and excellent analog input accuracy and resolution. The CR300 can measure most hydrological, meteorological, environmental, and industrial sensors. It concentrates data, makes it available over varied networks, and delivers it using your preferred protocol. It also performs automated on-site or remote decision making for control and M2M communications. The CR300 is ideal fo

Category:

The CR300 is a low-powered data logger designed to measure sensors, analyze data, and store data and programs. A battery-backed clock assures accurate timekeeping. The on-board, BASIC-like programming language—common to all Campbell Scientific data loggers—supports data processing and analysis routines.

The CR300 wiring panel includes a switchable 12 V terminal, and analog grounds dispersed among six analog terminals.

Benefits and Features

    • Connects directly to a computer’s USB port
    • Differentiates even slight changes in data values with higher resolutions measurements (24 bit Adc)
    • Provides simple serial sensor integration and measurement with SDI-12 and/or RS-232
    • Supports full PakBus networking
    • Includes embedded web page for direct connection via web browser
-NOTE- Additional specifications are listed in the CR300-Series Specifications Sheet.
Operating Temperature Range
  • -40° to +70°C (standard)
  • Non-condensing environment
Maximum Scan Rate 10 Hz
Case Material Powder-coated aluminum
Analog Inputs 6 single-ended or 3 differential (individually configured)
Pulse Counters 8 (P_SW, P_LL, C1, C2, and SE1 to SE4)
Voltage Excitation Terminals 2 (VX1, VX2)
Communications Ports
  • USB Micro B
  • RS-232
Switched 12 Volt 1 terminal
Digital I/O 7 terminals (C1, C2, P_SW, and SE1 to SE4) configurable for digital input and output. Includes status high/low, pulse width modulation, external interrupt, and communication functions. Exception: The SE4 terminal doesn’t do external interrupt.
Input Limits -100 to +2500 mV
Analog Voltage Accuracy
  • Accuracy specifications do not include sensor or measurement noise.
  • ±(0.04% of measurement + offset) at 0° to 40°C
  • ±(0.1% of measurement + offset) at -40° to +70°C
ADC 24-bit
Power Requirements 16 to 32 Vdc for charger input (CHG) (Current limited to 0.9 A maximum for power converter or solar panel input.)
Power Requirements 10 to 18 Vdc for external batteries (BAT)
Real-Time Clock Accuracy ±1 min. per month
Internet Protocols Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP(APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS
Communication Protocols PakBus, Modbus, DNP3, SDI-12, TCP, UDP, and others
CPU Drive/Programs 80 MB serial flash
Data Storage 30 MB serial flash
Idle Current Drain, Average 1.5 mA (@ 12 Vdc)
Active Current Drain, Average
  • 5 mA (@ 12 Vdc for 1 Hz scan with 1 analog measurement)
  • 23 mA (@ 12 Vdc with processor always on)
Dimensions 13.97 x 7.62 x 4.56 cm (5.5 x 3.0 x 1.8 in.)

Additional clearance required for cables and leads.

Weight 242 to 250 g (0.53 to 0.55 lb) depending on communication option selected
CR300-RF407 Option
Radio Type Frequency Hopping Spread Spectrum (FHSS)
Output Power 5 to 250 mW (user-selectable)
Frequency 902 to 928 MHz (US, Canada)
RF Data Rate 200 kbps
Receive Sensitivity -101 dBm
Antenna Connector RPSMA (External antenna required; see www.campbellsci.com/order/rf407 for Campbell Scientific antennas.)
Idle Current Drain, Average 12 mA (@ 12 Vdc)
Active Current Drain, Average < 80 mA (@ 12 Vdc)
CR300-RF412 Option
Radio Type Frequency Hopping Spread Spectrum (FHSS)
Output Power 5 to 250 mW (user-selectable)
Frequency 915 to 928 MHz (Australia, New Zealand)
RF Data Rate 200 kbps
Receive Sensitivity -101 dBm
Antenna Connector RPSMA (External antenna required; see www.campbellsci.com/order/rf412 for Campbell Scientific antennas.)
Idle Current Drain, Average 12 mA (@ 12 Vdc)
Active Current Drain, Average < 80 mA (@ 12 Vdc)
CR300-RF422 Option
Radio Type 868 MHz SRD 860 with Listen Before Talk (LBT) and Automatic Frequency Agility (AFA)
Output Power 2 to 25 mW (user-selectable)
Frequency 863 to 870 MHz (European Union)
RF Data Rate 10 kbps
Receive Sensitivity -106 dBm
Antenna Connector RPSMA (External antenna required; see www.campbellsci.com/order/rf422 for Campbell Scientific antennas.)
Idle Current Drain, Average 9.5 mA
Active Current Drain, Average 20 mA
CR300-RF427 Option
Radio Type Frequency Hopping Spread Spectrum (FHSS)
Output Power 5 to 250 mW (user-selectable)
Frequency 902 to 907.5 MHz/915 to 928 MHz (Brazil)
RF Data Rate 200 kbps
Receive Sensitivity –101 dBm
Antenna Connector RPSMA (External antenna required.)
Idle Current Drain, Average 12 mA (@ 12 Vdc)
Active Current Drain, Average < 80 mA (@ 12 Vdc)
CR300-WIFI Option
Operational Modes Client or Access Point
Operating Frequency 2.4 GHz, 20 MHz bandwidth
Antenna Connector Reverse Polarity SMA (RPSMA)
Antenna pn 16005 unity gain (0 dBd), 1/2 wave whip, omnidirectional with articulating knuckle joint for vertical or horizontal orientation
Transmit Power 7 to 18 dBm (5 to 63 mW)
CR300-CELL205 Option
-NOTE- The CR300-CELL205 option is not compatible with a Verizon cellular network.
Certifications IC (Industry Canada) 10224A-201611EC21A
Cell Technologies
  • 3G (UMTS/HSPA+)
  • 4G (LTE CAT-1)
3G Frequency Bands 850, 1700/2100 (AWS), and 1900
4G Frequency Bands 700, 850, 1700/2100 (AWS-1), 1900
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr300 for Campbell Scientific antennas.)
SIM Interface 3FF (6 position/contacts)

Supports SIMs that require 1.8 or 3 V.

Radio Output Power
  • 23 dBm on LTE
  • 24 dBm on UMTS
  • 27 dBm on EDGE
  • 33 dBm on GSM
Radio Sensitivity Range -99.5 to 110.5 dBm (10 M)
CR300-CELL210 Option
-NOTE- The CR300-CELL210 option is only compatible with a Verizon cellular network.
Cell Technologies 4G (LTE CAT-1)
4G Frequency Bands 700, 850, 1700, 1900, 2100
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr300 for Campbell Scientific antennas.)
Power Consumption – Low Power Mode 5 mA
Power Consumption – Idle 35 mA
Power Consumption – Active 70 mA
SIM Interface 3FF (6 position/contacts)

Supports SIMs that require 1.8 or 3 V.

Radio Output Power 23 dBm on LTE
Radio Sensitivity Range -99.5 to 110.5 dBm (10 M)
CR300-CELL215 Option
-NOTE- The CR300-CELL215 option is intended for use in EMEA countries.
Cell Technologies
  • 2G (GSM/GPRS/EDGE)
  • 3G (UMTS/HSPA+)
  • 4G (LTE CAT-1)
2G Frequency Bands 900 and 1800 MHz
3G Frequency Bands 850, 900, and 2100 MHz
4G Frequency Bands 800, 850, 900, 1800, 2100, and 2600 MHz
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr300 for Campbell Scientific antennas.)
SIM Interface 3FF (6 position/contacts)

Supports SIMs that require 1.8 or 3 V.

Radio Output Power
  • 23 dBm on LTE
  • 24 dBm on UMTS
  • 27 dBm on EDGE
  • 33 dBm on GSM
Radio Sensitivity Range -99.5 to 110.5 dBm (10 M)
CR300-CELL220 Option
-NOTE- The CR300-CELL220 option is intended for use in Australia and New Zealand.
Cell Technologies
  • 3G (UMTS/HSPA+)
  • 4G (LTE CAT-1)
3G Frequency Bands
  • 850 and 2100 MHz (EC-21AUT)
  • 850, 900, 1900, and 2100 MHz (EC-21AU)
4G Frequency Bands
  • 700, 850, 1800, 2100, and 2600 MHz (EC-21AUT)
  • 700, 900, 1700, 1800, 1900, 2100, and 2600 MHz (EC-21AU)
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr300 for Campbell Scientific antennas.)
SIM Interface 3FF (6 position/contacts)

Supports SIMs that require 1.8 or 3 V.

Radio Output Power
  • 23 dBm on LTE
  • 24 dBm on UMTS
Radio Sensitivity Range -99.5 to 110.5 dBm (10 M)
CR300-CELL225 Option
-NOTE- The CR300-CELL225 option is intended for use in Japan.
Cell Technologies 4G (LTE CAT-1)
4G Frequency Bands 800 (lower), 800 (upper), 850+, 900, 1800, and 2100 MHz
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr300 for Campbell Scientific antennas.)
SIM Interface 3FF (6 position/contacts)

Supports SIMs that require 1.8 or 3 V.

Radio Output Power 23 dBm on LTE
Radio Sensitivity Range -99.5 to 110.5 dBm (10 M)

Brochures: CR300 Datalogger

Download

Brochures: CR300-Series Specifications Sheet

Download

Brochures: Cellular Data Services

Download

Manuals: CR300 Series Getting Started Guide (PDF)

Download

Manuals: CR300 Series Product Manual (PDF)

Download

Product reviews

Review CR300 Measurement and Control Datalogger

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review CR300 Measurement and Control Datalogger
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Bộ thu thập và xử lý dữ liệu Granite 10

    Granite 10 Measurement and Control Data-Acquisition System

    Ideal for automotive testing applications, featuring CAN bus and CAN FD output
    Find out more
    Mô-đun Đầu vào Cổng Dòng điện 100 Ohm CURS100

    CURS100 100-Ohm Current Terminal Input Module

    Expands capabilities, allows data logger to measure additional types of sensors
    Find out more
    Datalogger ba kênh cho cảm biến dây rung CRVW3-NE

    CRVW3-NE Three-Channel Vibrating Wire Datalogger without Enclosure

    Vibrating Wire Data Logger Using patented VSPECT™ technology
    Find out more
    Bộ Ghi Dữ Liệu Dây Rung Ba Kênh CRVW3

    CRVW3 Three-Channel Vibrating Wire Datalogger

    Self-Contained Vibrating Wire Data Logger Using patented VSPECT® technology
    Find out more
    Bộ ghi đo tự động Datalogger CR6

    CR6 Automated Monitoring Platform

    Rugged, wireless edge device and gateway with built-in connectivity, designed for geotechnical, structural, and environmental projects
    Find out more
    Bộ ghi dữ liệu đo lường và điều khiển CR350

    CR350 Measurement and Control Datalogger

    Compact data logger with RS-485, ideal for small applications
    Find out more
    Bộ ghi dữ liệu đo lường và điều khiển CR310

    CR310 Measurement and Control Datalogger

    Compact data logger with ethernet, ideal for small applications
    Find out more
    Bộ ghi dữ liệu đo lường và điều khiển CR300

    CR300 Measurement and Control Datalogger

    Compact data logger, ideal for small applications
    Find out more


      Contact us

      error: Content is protected !!