109SS-L Stainless-Steel Temperature Probe

for Harsh Environments

The 109SS is a rugged, accurate probe that measures soil or water temperature from -40° to +70°C. The 109SS consists of a thermistor encased in a sheath made from grade 316L stainless steel. The rugged stainless-steel sheath protects the thermistor, allowing you to bury or submerge the 109SS in harsh, corrosive environments. This probe also has a fast time response, and it can be easily interfaced with our data loggers. 

Benefits and Features 

    • Designed for harsh, corrosive environments 
    • Fast response time 
    • Wide temperature measurement range 
    • Easy to install or remove 
    • Compatible with most of our current and retired data loggers 
Category:

The 109SS thermistor can survive temperatures up to 100°C, but the overmolded joint and cable should not be exposed to temperatures hotter than +70°C. 

Water Temperature 

The sensor can be submerged to 46 m (150 ft) or 63 psi. Please note that the 109SS is not weighted. Therefore, the installer should either add a weighting system or secure the sensor to a fixed, submerged object, such as a piling. 

Soil Temperature 

The 109SS is suitable for shallow burial only. Placement of the sensor’s cable inside a rugged conduit may be advisable for long cable runs—especially in locations subject to digging, mowing, traffic, use of power tools, or lightning strikes.

Output Analog
Operating Temperature Range -40° to +70°C
Accuracy
  • Note: Overall probe accuracy is a combination of thermistor interchangeability, bridge-resistor accuracy, and error of the Steinhart-Hart equation. Interchangeability is the principle component error. If needed, an estimate of the interchangeability error for 0 to 50°C, that can be used as the Offset parameter of the Therm109() instruction, can be determined with a 1-point or 2-point calibration.
  • ±0.60°C (-40 to +70°C)
  • ±0.49°C (-20 to +70°C)
Maximum Submergence 45.7 m (150 ft) or 434 kPa (63 psi)
Temperature Measurement Range -40° to +70°C
Thermistor Temperature Survival Range -50° to +100°C
Overmolded Joint and Cable Temperature Survival Range -50° to +70°C
Interchangeability Error
  • ±0.6°C tolerance (-40°C)
  • ±0.38°C tolerance (0°C)
  • ±0.1°C tolerance (25°C)
  • ±0.3°C tolerance (50°C)
  • ±0.4°C tolerance (70°C)
Steinhart-Hart Equation Error ≤ 0.02°C (-40°)
Time Constant in Air
  • 31 s (still air)
  • 7.5 s (air @ 3 m/s)
  • 0.5 s (antifreeze/water rolling)
Sensor Description Micro-BetaCHIP Probe 10K3MCD1, 0.5 mm (0.018 in.) diameter, 10 kohm at 25°C
Cable Description 0.56 cm (0.22 in.) diameter with Santoprene jacket
Cable/Probe Connection “ATUM” heat shrink, “Macromelt” overmolded joint
Stainless-Steel Sheath Diameter 0.16 cm (0.063 in.)
Stainless-Steel Sheath Length 5.84 cm (2.3 in.)
Overmolded Joint Diameter 1.02 cm (0.40 in.)
Overmolded Joint Length 4.24 cm (1.67 in.)
Weight 0.1 kg with 3.2 m cable (0.2 lb with 10.5 ft cable)

109SS Temperature Probe for Harsh Environments

Download

Product reviews

Review 109SS-L Stainless-Steel Temperature Probe

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review 109SS-L Stainless-Steel Temperature Probe
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Thiết bị đo độ dẫn điện Q46C 2E

    Q46C 2E Conductivity Monitor

    The reliable and accurate low-level water quality measurements required for such high purity water systems
    Find out more
    Thiết bị giám sát Clo Tổng Q46H/79PR

    Q46H/79PR Total Chlorine Monitor

    A highly versatile on-line, continuous measuring system
    Find out more
    Hệ thống phát hiện khí hai kênh IsoMon

    IsoMon Dual-Channel Gas Detection

    Monitors complete decontamination processes from start to finish, measuring both high and low gas concentration levels
    Find out more
    Thiết bị giám sát độ dẫn điện Q46C2 2E

    Q46C 2E Conductivity Monitor

    The reliable and accurate low-level water quality measurements required for such high purity water systems
    Find out more
    Máy đo Clo dư Q46H/62-63

    Q46H/62-63 Residual Chlorine Monitor

    Easy online monitoring and control of chlorination systems, with minimal maintenance
    Find out more
    Thiết bị giám sát Hydro Peroxide Q46/84

    Q46/84 Hydrogen Peroxide Monitor

    Offers continuous measurement of H2O2 concentrations in aqueous systems
    Find out more
    Thiết bị giám sát Axit Peracetic Q46/85

    Q46/85 Peracetic Acid Monitor

    An on-line water quality monitor capable of providing real time measurement of low levels of PAA in solution
    Find out more
    Hệ thống giám sát khí GasSens Midi

    GasSens Midi Controller

    An addressable monitoring system, providing a stand-alone measurement and logging solution for hazardous area sensing
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!