Q46S/81 Dissolved Sulfide Monitor

Provides an improved method for measuring sulfides in solution

Key benefits

  • Improved method for measuring sulfides in solution
  • No contact between sensor and water sample

Applications

The Q46S/81 Dissolved Sulfide Monitor is available for a wide range of applications including:

  • Well Water
  • Waste Water
  • Tanning Waste
Category:

High sensitivity sulfide monitoring

Sulfides can be found naturally in well water and can build up in wastewater collection systems due to anaerobic conditions frequently found there. In addition, sulfides are used in mercury removal processes and are frequently found in tanning wastes. In drinking water systems, sulfides cause taste and odor problems. In wastewater systems, sulfides cause damage to concrete structures in collection systems and contribute to odor problems in treatment facilities.

Measurement of dissolved sulfide concentrations has been done primarily by the use of analyzers employing ion selective electrodes (ISE) for sensing. While providing adequate sensitivity, ISE based systems require frequent zero and span adjustments to maintain measurement accuracy. Because of this, most ISE based monitoring systems are relatively expensive and require frequent service.

Due to measuring sulfides in solution being relatively difficult, the Q46S/81 Monitor takes a different approach to the measurement, employing a unique gas-phase method to continuously monitor sulfide without contact between the sensor and the water sample. In operation, a small amount of sample is pumped into the system and mixed with acid. In acidic solution, the sulfide ion is converted to hydrogen sulfide gas The mixed sample flows into a special chamber where the hydrogen-sulfide is stripped from the sample. A gas conditioning module prepares the gas sample for measurement prior to contact with a special H2S gas sensor designed for the system. Sensor signals are amplified and displayed on a large-format, backlit LCD display in the Q46S electronics unit.

Features & specifications

  • Sulfide Measurement
  • Gas Phase Sensing
  • Chemistry Module Power Options
  • Three Control Relays
  • Sample Line Cleaning
  • Digital Communications Option
Q46S/81 SPECIFICATIONS
Display Range 0-2.000 or 0-20.00 PPM
Accuracy ±0.002 PPM
Repeatability ±0.002 PPM
Linearity 0.5% of F.S.
Zero Drift < 0.005 PPM per month
Power 100-240 VAC ±10%, 50/60 Hz
Analog Outputs Two isolated 4-20 mA, 500 Ω load max
Relays Three SPDT, 6A @250 VAC, 5A @24 VDC
Display 4-digit, 0.75″ numeric LCD with 12-digit second line, LED backlight
Enclosure NEMA 4X (IP-66) Polycarbonate, V-0 flammability
Operating Temperature -20 to 60°C (-4 to 140°F)
Weight 2.5 lbs (1.1 kg)
CHEMISTRY MODULE
Sulfide Sensor Membrane H₂S Gas Sensor
Sensor Cable 25 ft standard, 100 ft max
Response Time 95% within 3 minutes
Sample Pump Internal tubing pump, 7 cc/min
Acid Pump Internal tubing pump, 0.1 cc/min
Air Supply Diaphragm air pump with precision flow control
Air Stripping Chamber Cast Acrylic
Inlet Sample Flow Rate 5-20 GPH at inlet overflow assembly
Sample Inlet 1/4″ I.D. Hose Barb
Sample Drain 1/2″ I.D. Hose Barb
Power 115 or 230 VAC (customer specified)
Operating Temperature 2 to 50°C
Enclosure Kydek with acrylic cover, V-0 flammability
Weight 15 lbs (6.8 kg)

ORDERING INFORMATION

  • Model Q46S/81-A-B Sulfide Monitor
    • Suffix A – Power
      • 1 – 115 VAC, 50/60 Hz
      • 2 – 230 VAC, 50/60 Hz
    • Suffix B – Digital Output
      • 1 – None
      • 2 – Profibus-DP
      • 3 – Modbus-RTU
      • 4 – Ethernet-IP

ACCESSORIES

  • 31-0038: 7-c Sensor interconnect cable, 100 ft max
  • 05-0094: Panel Mount Bracket Kit
  • 47-0005: 2″ U-bolt, 304SS

Q46S/81 Dissolved Sulfide Monitor

Download

Product reviews

Review Q46S/81 Dissolved Sulfide Monitor

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Q46S/81 Dissolved Sulfide Monitor
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Thiết bị giám sát Hydro Peroxide Q46/84

    Q46/84 Hydrogen Peroxide Monitor

    Offers continuous measurement of H2O2 concentrations in aqueous systems
    Find out more
    Thiết bị giám sát Axit Peracetic Q46/85

    Q46/85 Peracetic Acid Monitor

    An on-line water quality monitor capable of providing real time measurement of low levels of PAA in solution
    Find out more
    Thiết bị giám sát Sulfide Q46S/81

    Q46S/81 Dissolved Sulfide Monitor

    Provides an improved method for measuring sulfides in solution
    Find out more
    Thiết bị giám sát độ dẫn điện kiểu Toroidal Q46CT

    Q46CT Toroidal Conductivity Monitor

    Meet virtually any conductivity water quality monitoring and control application
    Find out more
    Thiết bị giám sát Ozone hòa tan trong nước Q46H/64

    Q46H/64 Dissolved Ozone Monitor

    Water quality monitoring and controlling ozone treatment systems
    Find out more
    Thiết bị giám sát quy trình rửa ngược FilterSmart

    FilterSmart Gravity Filter Backwash Monitor

    Allows water managers to monitor the backwashing process by measuring filter media level and turbidity with a single sensor
    Find out more
    Máy đo Ammonia hòa tan trong nước Q46N

    Q46N Dissolved Ammonia Monitor

    Real-time monitoring of Free and Total Ammonia for a variety of applications
    Find out more
    Máy đo độ dẫn điện Q46C4 4E

    Q46C4 4E Conductivity Monitor

    The solution for almost any water-based process monitoring
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!