Q46S/81 Dissolved Sulfide Monitor

Provides an improved method for measuring sulfides in solution

Key benefits

  • Improved method for measuring sulfides in solution
  • No contact between sensor and water sample

Applications

The Q46S/81 Dissolved Sulfide Monitor is available for a wide range of applications including:

  • Well Water
  • Waste Water
  • Tanning Waste
Category:

High sensitivity sulfide monitoring

Sulfides can be found naturally in well water and can build up in wastewater collection systems due to anaerobic conditions frequently found there. In addition, sulfides are used in mercury removal processes and are frequently found in tanning wastes. In drinking water systems, sulfides cause taste and odor problems. In wastewater systems, sulfides cause damage to concrete structures in collection systems and contribute to odor problems in treatment facilities.

Measurement of dissolved sulfide concentrations has been done primarily by the use of analyzers employing ion selective electrodes (ISE) for sensing. While providing adequate sensitivity, ISE based systems require frequent zero and span adjustments to maintain measurement accuracy. Because of this, most ISE based monitoring systems are relatively expensive and require frequent service.

Due to measuring sulfides in solution being relatively difficult, the Q46S/81 Monitor takes a different approach to the measurement, employing a unique gas-phase method to continuously monitor sulfide without contact between the sensor and the water sample. In operation, a small amount of sample is pumped into the system and mixed with acid. In acidic solution, the sulfide ion is converted to hydrogen sulfide gas The mixed sample flows into a special chamber where the hydrogen-sulfide is stripped from the sample. A gas conditioning module prepares the gas sample for measurement prior to contact with a special H2S gas sensor designed for the system. Sensor signals are amplified and displayed on a large-format, backlit LCD display in the Q46S electronics unit.

Features & specifications

  • Sulfide Measurement
  • Gas Phase Sensing
  • Chemistry Module Power Options
  • Three Control Relays
  • Sample Line Cleaning
  • Digital Communications Option
Q46S/81 SPECIFICATIONS
Display Range 0-2.000 or 0-20.00 PPM
Accuracy ±0.002 PPM
Repeatability ±0.002 PPM
Linearity 0.5% of F.S.
Zero Drift < 0.005 PPM per month
Power 100-240 VAC ±10%, 50/60 Hz
Analog Outputs Two isolated 4-20 mA, 500 Ω load max
Relays Three SPDT, 6A @250 VAC, 5A @24 VDC
Display 4-digit, 0.75″ numeric LCD with 12-digit second line, LED backlight
Enclosure NEMA 4X (IP-66) Polycarbonate, V-0 flammability
Operating Temperature -20 to 60°C (-4 to 140°F)
Weight 2.5 lbs (1.1 kg)
CHEMISTRY MODULE
Sulfide Sensor Membrane H₂S Gas Sensor
Sensor Cable 25 ft standard, 100 ft max
Response Time 95% within 3 minutes
Sample Pump Internal tubing pump, 7 cc/min
Acid Pump Internal tubing pump, 0.1 cc/min
Air Supply Diaphragm air pump with precision flow control
Air Stripping Chamber Cast Acrylic
Inlet Sample Flow Rate 5-20 GPH at inlet overflow assembly
Sample Inlet 1/4″ I.D. Hose Barb
Sample Drain 1/2″ I.D. Hose Barb
Power 115 or 230 VAC (customer specified)
Operating Temperature 2 to 50°C
Enclosure Kydek with acrylic cover, V-0 flammability
Weight 15 lbs (6.8 kg)

ORDERING INFORMATION

  • Model Q46S/81-A-B Sulfide Monitor
    • Suffix A – Power
      • 1 – 115 VAC, 50/60 Hz
      • 2 – 230 VAC, 50/60 Hz
    • Suffix B – Digital Output
      • 1 – None
      • 2 – Profibus-DP
      • 3 – Modbus-RTU
      • 4 – Ethernet-IP

ACCESSORIES

  • 31-0038: 7-c Sensor interconnect cable, 100 ft max
  • 05-0094: Panel Mount Bracket Kit
  • 47-0005: 2″ U-bolt, 304SS

Q46S/81 Dissolved Sulfide Monitor

Download

Product reviews

Review Q46S/81 Dissolved Sulfide Monitor

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Q46S/81 Dissolved Sulfide Monitor
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Cảm biến đo chất rắn lơ lửng soli::lyser

    soli::lyser Suspended Solids Physical Sensor

    Measure the concentration of suspended solids directly in water
    Find out more
    Cảm biến đo thế oxy hóa khử redo::lyser

    redo::lyser Redox Potential Physical Sensor

    On-line measurement of the redox potential immersed in a medium or in a flow cell
    Find out more
    Thiết bị Terminal con::lyte

    con::lyte Terminal

    Find out more
    Cảm biến đo amoni ammo::lyser

    ammo::lyser Pro Ammonium Physical Sensor

    A multiparameter probe for online ammonium measurement
    Find out more
    Đầu dò quang phổ multi::lyser V3

    multi::lyser V3 Spectrometer Probe

    Measure organic carbon and nitrate of surface water, groundwater, drinking water and wastewater
    Find out more
    Đầu dò quang phổ đo độ đục và TSS uv::lyser V3

    uv::lyser V3 Turbidity & Total Suspended Solids Spectrometer Probe

    Ideal for surface water, groundwater, drinking water and wastewater applications.
    Find out more
    Terminal giám sát nước thông minh Con::line

    con::line Water Monitoring Terminal

    The conline is a smart water monitoring terminal designed to seamlessly integrate with the complete Badger Meter sensors offering, M-Nodes and to third-party sensors
    Find out more
    Thiết bị IoT Terminal con::cube V3

    con::cube V3 IoT Terminal

    A versatile terminal for data acquisition and station control
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!