Q46P/R pH/ORP Monitor

Q46P/R pH & ORP water quality monitor provides the durability, accuracy and versatility required for pH and ORP monitoring or control applications

Key benefits

  • Differential or conventional pH sensors available
  • Automatic buffer recognition simplifies calibration
  • Q-Blast sensor cleaning option available
  • Multiple sensor mounting options

Applications

The Q46P pH/ORP Monitor is available for a wide range of applications including:

  • Water and wastewater
  • Boiler feed water
  • High purity water
  • Food processing wash water
  • Chemical plant cooling water
  • Many other aqueous systems that require reliable pH monitoring
Category:

The versatile Q46P/R system monitors Potential of Hydrogen (pH) and Oxidation Reduction Potential (ORP). The differential pH/ORP sensors make use of a sealed reference system – a second glass pH electrode – to help prevent the destruction of the sensor, from chemical poisons including sulfide, cyanide, chlorine and bisulfite.

Within the sensor, the integral preamplifier creates a low impedance signal output. This helps to provide consistent readings in all environments, maximising the distance between sensor and analyser.

The addition of ATi’s Q-Blast option provides the ideal answer for automatic pH or ORP sensor cleaning. Employing a unique ‘air-blast’ cleaning method, sensors can be cleaned as often as necessary without operator attention.

Features & specification

  • Choice of either “differential” or “conventional” pH sensors.
  • Auto-Cleaning
  • Automatic buffer recognition simplifies calibration.
  • Power options include universal 100-240 VAC or 12-24 VDC.
  • Two isolated 4-20 mA outputs are standard, with an option for a third output if required. Default setting provides analog outputs for pH/ORP and temperature.
  • Standard PID control function assignable to one analog output.
  • Available for either Profibus-DP, Modbus-RTU, or Ethernet-IP.
  • Three SPDT relays are standard, with relay functions programmable for alarm, control, or trouble indication. Three additional low power relays available as an option.
  • NEMA 4X (IP-66) enclosure is suitable for wall, pipe, or panel mounting.
  • Back-lit large LCD display provides clear visibility in any lighting conditions. A scrolling second line on the display provides additional information and programming prompts.

ELECTRONIC MONITOR SPECIFICATIONS

Display Range [pH] 0 to 14

[ORP] -1000 to +2000 mV

Accuracy 0.5% of selected range
Repeatability 0.3% of selected range
Non-Linearity 0.1% of selected range
Temperature Drift 0.01% of span/°C
Power 100-240 VAC ±10%, 50/60 Hz, 10 VA max;

12-24 VDC, 500 mA max

Analog Outputs Two isolated 4-20 mA, 500 Ω load max (3rd output optional)
Relays Three SPDT, 6A @250 VAC, 5A @24 VDC

(3 additional SPST non-isolated, 1A @30 VDC optional)

Display 4-digit, 0.75″ numeric LCD with 12-digit second line, LED back light
Enclosure NEMA 4X (IP-66) Polycarbonate, V-0 flammability
Operating Conditions -20 to 60°C (-4 to 140°F)
Weight 6 lbs (2.7 kg) with sensor, flowcell, and accessories
Digital Output Options for Profibus DP, Modbus RTU, or Ethernet IP

 

SENSOR SPECIFICATIONS

Measuring Range 0 to 14 pH, -1000 to +2000 mV
Sensitivity 0.002 pH; 0.2 mV
Stability 0.02 pH; 2 mV (per 24 hours, non-cumulative)
Wetted Materials PEEK, ceramic, titanium, glass, Viton, EPDM, Platinum or Gold (ORP only), 316SS with Sanitary or insertion body styles
Temperature Compensation Pt1000 RTD
Sensor Cable 6 conductor plus 2 shields, HDPE jacket
Temperature Range -5 to 95°C (23 to 203°F)
Pressure Range 0-100 PSIG
Max. Flow Rate 10 ft (3 m) per second
Max. Sensor to Analyzer Distance 3,000 ft (914 m)
Sensor Body Options 1″ NPT Convertible

1-1/4″ Insertion

1-1/2″ or 2″ Sanitary-style

Q46P/R pH/ORP Monitor

Download

Product reviews

Review Q46P/R pH/ORP Monitor

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Q46P/R pH/ORP Monitor
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Cảm biến đo chất rắn lơ lửng soli::lyser

    soli::lyser Suspended Solids Physical Sensor

    Measure the concentration of suspended solids directly in water
    Find out more
    Cảm biến đo thế oxy hóa khử redo::lyser

    redo::lyser Redox Potential Physical Sensor

    On-line measurement of the redox potential immersed in a medium or in a flow cell
    Find out more
    Thiết bị Terminal con::lyte

    con::lyte Terminal

    Find out more
    Cảm biến đo amoni ammo::lyser

    ammo::lyser Pro Ammonium Physical Sensor

    A multiparameter probe for online ammonium measurement
    Find out more
    Đầu dò quang phổ multi::lyser V3

    multi::lyser V3 Spectrometer Probe

    Measure organic carbon and nitrate of surface water, groundwater, drinking water and wastewater
    Find out more
    Đầu dò quang phổ đo độ đục và TSS uv::lyser V3

    uv::lyser V3 Turbidity & Total Suspended Solids Spectrometer Probe

    Ideal for surface water, groundwater, drinking water and wastewater applications.
    Find out more
    Terminal giám sát nước thông minh Con::line

    con::line Water Monitoring Terminal

    The conline is a smart water monitoring terminal designed to seamlessly integrate with the complete Badger Meter sensors offering, M-Nodes and to third-party sensors
    Find out more
    Thiết bị IoT Terminal con::cube V3

    con::cube V3 IoT Terminal

    A versatile terminal for data acquisition and station control
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!