Q46D Dissolved Oxygen Monitor

Provide accurate, reliable oxygen measurement and help reduce operating costs

Dissolved Oxygen Monitoring is critical to stable operation of biological processes in wastewater treatment plants.

Key benefits

  • Q-Blast AutoClean
  • Optical and galvanic options
  • All digital communications

Applications

  • Biological processes in wastewater treatment plants
  • Better results with fine bubble aeration, coarse bubble aeration, surface aeration or brush aerators
  • Ideal for control applications where reliable performance is required 365 days a year
Category:

Dissolved Oxygen water quality monitoring is critical for aeration system process control. Optimization of the biological process, whether it’s removal of organic material, nitrification, or nitrification/denitrification, depends on maintaining proper D.O. levels. Controlling air flow to within the optimal range eliminates excess aeration, which translates into significant energy savings.

ATi’s Q46D Dissolved Oxygen Monitor is designed to provide reliable oxygen measurement and help reduce operating costs. Two types of sensing technologies are available for use with the Q46D system: Membraned Electrochemical and Optical (fluorescence). Both sensors will provide reliable long-term performance with minimal maintenance. No hardware modifications are required to change from one sensor type to the other. The monitor can be configured for AC or DC power supplies, and a portable battery-powered unit is available to meet a variety of monitoring needs. When process conditions require frequent sensor cleaning, our unique Q-Blast Auto-Cleaner can be used to keep the system operating nearly maintenance free. This time-proven system has been instrumental in providing years of worry free operation.

Features & specification

  • Optical or galvanic membraned sensor options
  • Auto-Clean ‘Air Blast’ sensor cleaning system available
  • Automatic calibration check
  • AC or DC Power Options
  • 3 Analog Output Option
  • PID Output
  • Profibus-DP, Modus-RTU or Ethernet-IP Digital Communications Available
  • 6 Relay contact options
  • Flexible mounting options
  • Large, back-lit LCD display
Display Range 0 – 40.00 PPM (or mg/L); 0-200% saturation
Accuracy 0.5% of selected range or 0.02 PPM
Repeatability 0.3% of selected range or 0.01 PPM
Non-Linearity 0.1% of selected range
Temperature Drift 0.01% of span/°C
Power 90-260 VAC, 50/60 Hz, 10VA max.; 12-24 VDC, 500 mA max.
Analog Outputs Two isolated 4-20 mA, 500Ω load max. (3rd output optional)
Relays Three SPDT, 6A @250 VAC, 5A @24VDC
Display 4 digit, 0.75” numeric LCD with 12 character second line
Enclosure NEMA 4X (IP-66) Polycarbonate, V-0 flammability
Operating Temperature -20 to 60°C (-4 to 140°F)
Weight 4 lbs. (1.8 kg); Auto-Clean version: 18 lbs (8.1 kg)
Sensor Options Optical Fluorescence Quenching or Membrane-Covered Galvanic (flow type or submersible)

Note:

  • All systems with membraned sensors are supplied with one package of membranes, one 120 cc bottle of electrolyte, and one spare parts kit.
  • Pipe mount requires two 2” U-bolts (47-0005).
  • When Auto-Clean option is selected, you must also select option 3 in Suffix E.
OPTICAL SENSOR SPECIFICATIONS
Range 0-40 PPM
Wetted Materials PVC
Optical Element Replacement Replacement Disk, 2-5 year life
Cable Length 30 ft (9.2 m) standard, up to 200 ft (61 m) with junction box
Response Time 90% in 3 minutes
Operating Temp. -5 to 50°C
Size 2.4” D x 5.5” L (6.1 x 14 cm)
Weight 2 lbs (0.9 kg)

 

GALVANIC SENSOR SPECIFICATIONS
Range 0-40 PPM
Wetted Materials Noryl, PVC, & 316SS
Membrane/Response 5 mil – 90% in 3 minutes (standard)
2 mil – 90% in 1 minute (optional)
Cable Length 30 ft (9.2 m) standard, up to 1000 ft (307 m) with junction box
Operating Temp. -5 to 50°C
Size (Auto-Clean) 2.4” D x 5.5” L (6.1 x 14 cm)
Weight 2 lbs (0.9 kg)
Size (Standard) 1.8” D x 6” L (4.6 x 15.2 cm)

 

ACCESSORIES
00-0628 Submersion mounting bracket kit for standard sensors
00-0629 Mounting kit for Auto-Clean sensor with rag shedder
07-0100 Junction Box, NEMA 4X
31-0038 7-conductor optical sensor cable, 300 ft max.
31-0001 5-conductor sensor interconnect cable (max. 1000 ft)
00-0624 Mounting bracket kit for Auto-Clean sensor
45-0043 Pipe adapter for Auto-Clean sensor
05-0094 Panel mount bracket kit
47-0005 2” U-bolt, 304SS
00-1637 Q-Blast Assembly with Power J-Box and Mounting Rails
00-0625 1-½” flow tee assembly
00-0043 Constant-head flowcell
00-1522 Sealed flowcell

Q46D Dissolved Oxygen Monitor Product Literature

Download

Product reviews

Review Q46D Dissolved Oxygen Monitor

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Q46D Dissolved Oxygen Monitor
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Thiết bị giám sát độ dẫn điện Q46C2 2E

    Q46C 2E Conductivity Monitor

    The reliable and accurate low-level water quality measurements required for such high purity water systems
    Find out more
    Máy đo Clo dư Q46H/62-63

    Q46H/62-63 Residual Chlorine Monitor

    Easy online monitoring and control of chlorination systems, with minimal maintenance
    Find out more
    Thiết bị giám sát Hydro Peroxide Q46/84

    Q46/84 Hydrogen Peroxide Monitor

    Offers continuous measurement of H2O2 concentrations in aqueous systems
    Find out more
    Thiết bị giám sát Axit Peracetic Q46/85

    Q46/85 Peracetic Acid Monitor

    An on-line water quality monitor capable of providing real time measurement of low levels of PAA in solution
    Find out more
    Thiết bị giám sát Sulfide Q46S/81

    Q46S/81 Dissolved Sulfide Monitor

    Provides an improved method for measuring sulfides in solution
    Find out more
    Thiết bị giám sát độ dẫn điện kiểu Toroidal Q46CT

    Q46CT Toroidal Conductivity Monitor

    Meet virtually any conductivity water quality monitoring and control application
    Find out more
    Thiết bị giám sát Ozone hòa tan trong nước Q46H/64

    Q46H/64 Dissolved Ozone Monitor

    Water quality monitoring and controlling ozone treatment systems
    Find out more
    Thiết bị giám sát quy trình rửa ngược FilterSmart

    FilterSmart Gravity Filter Backwash Monitor

    Allows water managers to monitor the backwashing process by measuring filter media level and turbidity with a single sensor
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!