IsoMon Dual-Channel Gas Detection

Monitors complete decontamination processes from start to finish, measuring both high and low gas concentration levels

Key benefits

  • Monitor complete decontamination cycles from start to finish
  • High and low value measurement of hydrogen peroxide values
  • Provides reliable validation data

Applications

The IsoMon is available for a wide range of applications including:

  • Pharmaceutical
  • Biological
  • Medical device manufacturing
  • Defence
  • Industrial
  • Healthcare
  • Food packaging
Category:

Dual channel gas monitoring for high & low levels

ATi’s IsoMon dual-channel gas detection system has revolutionised the way sterilisation cycles are processed, monitoring the complete decontamination process from start to finish and measuring gas levels of both high and low concentration.

This unique system has been primarily developed to address the sterilisation needs of the pharmaceutical, biological, medical device manufacturing, defence, industrial, healthcare and food packaging industries, but can also be deployed to reduce the occurrence of hospital-acquired infections and even the decontamination of aircraft cabins.

IsoMon is a first-of-its-kind gas detector that allows both high and low value measurements of Hydrogen Peroxide levels, providing users with reliable validation data regarding the sterilisation of aseptic environments and that they are safe following sterilisation.

Features & specification

  • Gas Type: Channel 1 – Hydrogen Peroxide, 0-2000 PPM, Channel 2 – Hydrogen Peroxide, 0-100 PPM
  • Sensor Type: Electrochemical
  • Response Time: 90% in 60 seconds
  • Accuracy: Generally ±10% of value, but limited by available calibration gas accuracy
  • Repeatability: ± 20 PPM on 0-2000 range, ± 1 PPM on 0-100 range
  • Electronic Linearity: ±0.5%
  • Zero Drift
  • Display: Backlit graphics liquid crystal display
  • Outputs: 2 RS-232 outputs for stored gas values, 2 4-20 mA DC analog outputs for remote display
  • Memory: 12,000 data points per measuring channel
  • Programmable storage Interval options
  • Typical Capacity: 8 Days at 1-minute storage interval
  • Alarms: 3 concentration alarms with adjustable setpoints per channel. Alarms may be set for high, low, or off.
  • Power: 120 VAC or 230 VAC VAC
Specification
Gas Type Channel 1 – Hydrogen Peroxide, 0-2000 PPM

Channel 2 – Hydrogen Peroxide, 0-100 PPM

Sensor Type Electrochemical
Response Time 90% in 60 seconds
Accuracy Generally ±10% of value, but limited by available calibration gas accuracy
Repeatability ± 20 PPM on 0-2000 range

± 1 PPM on 0-100 range

Electronic Linearity ±0.5%
Zero Drift Less than 1% full scale per month, non-cumulative
Display Backlit graphics liquid crystal display
Outputs Two RS-232 outputs for stored gas values

Two 4-20 mA DC analog outputs for remote display

Memory 12,000 data points per measuring channel
Storage Interval Programmable for 1, 2, 3, 4, 5, 6, 10, 12, 15, 30, or 60 seconds
Typical Capacity 8 days at 1-minute storage interval
Alarms Three concentration alarms with adjustable setpoints per channel. Alarms may be set for high, low, or off. (Default is OFF. Alarms displayed on LCD and indicated by audible beeper.)
Power 120 VAC or 230 VAC
Operating Temperature -5ºC to +45ºC
Humidity 0-95% Non-condensing
Weight 10 lbs (4.5 Kg)

IsoMon Dual-Channel Gas Detection

Download

Product reviews

Review IsoMon Dual-Channel Gas Detection

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review IsoMon Dual-Channel Gas Detection
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Hệ thống phát hiện khí hai kênh IsoMon

    IsoMon Dual-Channel Gas Detection

    Monitors complete decontamination processes from start to finish, measuring both high and low gas concentration levels
    Find out more
    Thiết bị giám sát độ dẫn điện Q46C2 2E

    Q46C 2E Conductivity Monitor

    The reliable and accurate low-level water quality measurements required for such high purity water systems
    Find out more
    Máy đo Clo dư Q46H/62-63

    Q46H/62-63 Residual Chlorine Monitor

    Easy online monitoring and control of chlorination systems, with minimal maintenance
    Find out more
    Thiết bị giám sát Hydro Peroxide Q46/84

    Q46/84 Hydrogen Peroxide Monitor

    Offers continuous measurement of H2O2 concentrations in aqueous systems
    Find out more
    Thiết bị giám sát Axit Peracetic Q46/85

    Q46/85 Peracetic Acid Monitor

    An on-line water quality monitor capable of providing real time measurement of low levels of PAA in solution
    Find out more
    Hệ thống giám sát khí GasSens Midi

    GasSens Midi Controller

    An addressable monitoring system, providing a stand-alone measurement and logging solution for hazardous area sensing
    Find out more
    Thiết bị giám sát Sulfide Q46S/81

    Q46S/81 Dissolved Sulfide Monitor

    Provides an improved method for measuring sulfides in solution
    Find out more
    Thiết bị giám sát độ dẫn điện kiểu Toroidal Q46CT

    Q46CT Toroidal Conductivity Monitor

    Meet virtually any conductivity water quality monitoring and control application
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!