B12 2-Wire Gas Transmitter

A loop-powered transmitter for toxic gas detection with multiple sensor mounting configurations.

Key benefits

  • Capable of monitoring a large range of gases
  • Suitable for applications requiring battery operation
Category:

ATi’s B12 2-Wire Gas Detector is a loop-powered transmitter for toxic gas detection with multiple sensor mounting configurations.

Monitoring hazardous gases in ambient air

ATi’s B12 2-Wire Gas Detectors are loop-powered instruments that transmit a 4-20 mA signal linearly proportional to gas concentration. Operated from a 24 VDC power supply, the transmitter will drive loads up to 675 ohms, sufficient for most monitoring applications. Alternatively, the unit can operate at 12 VDC with reduced output load for applications requiring battery operation.

These detectors are normally supplied with the sensor close coupled to the enclosure. However, for special applications, the unit can be supplied with separate sensors that can be located up to 25 feet from the transmitter. Sensor duct mounting adapters and sensor flowcells can also be provided for specific applications. Contact ATi with details of any special requirements.

Features & specifications

  • Wide range of gases available from sensor list
  • Loop-powered 4–20 mA, 675 ohms maximum at 24 VDC
  • 12–30 VDC
  • Explosion-proof enclosure optional, Class 1, Div., 1, Groups B, C, & D
  • Operating temperature between -30° to +55°C (except oxygen, which is -10° to +55°C)
  • Sensor Pressure Limits: 7–30 PSIA (0.5–2 Bar)
  • Optional 3-Digit LCD

Specifications

Item Description
Gas Type Customer-selected from available sensor list
Range Supplied with standard range for each gas unless otherwise specified
Accuracy Generally ±5% of value, but limited by available calibration gas accuracy
Electronic Repeatability ±1% of full scale
Electronic Linearity ±0.5% of full scale
Zero Drift Sensor dependent, but generally less than 2% of full scale per month, non-cumulative
Span Drift Application dependent, but generally less than 3% per month
Output Loop-powered 4-20 mA, 675 ohms maximum at 24 VDC
Power 12–30 VDC
Enclosure NEMA 4X Polystyrene, optional explosion-proof enclosure, Class 1, Div. 1, Groups B, C & D
Controls Zero and span potentiometers mounted on transmitter circuit board
Operating Temperature -30° to +55°C (except oxygen, which is -10° to +55°C)
Sensor Pressure Limits 7–30 PSIA (0.5–2 Bar)
Weight 0.25 lbs (0.12 kg); 1.75 lbs (0.8 kg) for explosion-proof unit
Display Optional 3-Digit LCD (not available with explosion-proof enclosure)

Gas & Range Availability

Gas Minimum Range Maximum Range
Ammonia 0-100 PPM 0-2000 PPM
Carbon Monoxide 0-100 PPM 0-1000 PPM
Hydrogen 0-1000 PPM 0-10%
Nitric Oxide 0-50 PPM 0-500 PPM
Oxygen 0-5% 0-30%
Phosgene 0-1 PPM 0-100 PPM
Bromine 0-1 PPM 0-20 PPM
Chlorine 0-1 PPM 0-200 PPM
Chlorine Dioxide 0-1 PPM 0-200 PPM
Fluorine 0-1 PPM 0-200 PPM
Iodine 0-1 PPM 0-200 PPM
Ozone 0-1 PPM 0-200 PPM
Hydrogen Peroxide 0-1 PPM 0-200 PPM
Hydrogen Cyanide 0-1 PPM 0-200 PPM
Hydrogen Fluoride 0-1 PPM 0-200 PPM
Hydrogen Sulfide 0-10 PPM 0-500 PPM
Sulfur Dioxide 0-10 PPM 0-200 PPM
Arsine 0-1000 PPB 0-200 PPM
Diborane 0-1000 PPB 0-200 PPM
Germane 0-1000 PPB 0-200 PPM
Hydrogen Selenide 0-1000 PPB 0-200 PPM
Phosphine 0-1000 PPB 0-200 PPM
Silane 0-10 PPM 0-200 PPM
Iodine 0-2 PPM 0-200 PPM
Acid Gases 0-10 PPM 0-200 PPM
Ethylene Oxide 0-20 PPM 0-200 PPM
Formaldehyde 0-20 PPM 0-200 PPM
Alcohol 0-500 PPM 0-2000 PPM
Acetylene 0-500 PPM 0-2000 PPM

How To Order

Model B12-CC-D-EEEE 2-Wire Gas Transmitter

  • Suffix CC: Gas Type – Standard range shown in parentheses
  • Suffix D: Transmitter Enclosure Type
  • Suffix EEEE: Measurement Range
  • Suffix F: Units of Measurement

Accessories

Code Description
00-0118 Calibration adapter for standard sensors
00-0258 Calibration adapter for explosion-proof sensors
45-0046 Rain shield for explosion-proof sensors
00-0261 Remote calibration adapter
00-0255 Flowcell assembly for A10 standard sensor
00-0298 Flowcell assembly for C10 explosion-proof sensors

B12 2-Wire Gas Transmitter

Download

Product reviews

Review B12 2-Wire Gas Transmitter

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review B12 2-Wire Gas Transmitter
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Bộ ghi dữ liệu áp suất tức thời PIPEMINDER-ONE External

    PIPEMINDER-ONE External Transient Pressure Data Logger

    Suitable for wastewater, enables asset monitoring, pump performance alerts and more
    Find out more
    Bộ ghi dữ liệu áp suất PIPEMINDER-ONE Standard

    PIPEMINDER-ONE Standard Pressure Transient Data Logger

    High-resolution pressure data recording provides instantaneous and burst pressure detection
    Find out more
    Bộ ghi dữ liệu cảm biến âm thanh PIPEMINDER-ONE

    PIPEMINDER-ONE Acoustic Sensor Data Logger

    Combines acoustic and pressure monitoring for precise leak
    Find out more
    Máy nén khí cho đầu dò và cảm biến quang phổ

    Air Compressor for Spectrometer Probes and Sensors

    Provides compressed air for oxilyser, solilyser, ammolyser and spectrometer probes
    Find out more
    Thiết bị đo clo di động ChlorNet

    ChlorNet Portable Chlorine Monitor

    Provides mobile, accurate, reliable and real-time chlorine data
    Find out more
    Thiết bị đo khí Chlorine Dioxide Q45H/65

    Q45H/65 Chlorine Dioxide Transmitter

    Online water quality monitoring and control of industrial disinfection systems
    Find out more
    Thiết bị đo ozone hòa tan Q45H/64

    Q45H/64 Dissolved Ozone Transmitter

    Online water quality monitoring and control of ozonation system
    Find out more
    Thiết bị đo độ dẫn điện kiểu Toroidal Q45CT

    Q45CT Toroidal Conductivity Transmitter

    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!