AirmoVOC C2-C6 Light Volatile Hydrocarbon Analyzer

Measures light volatile hydrocarbon compounds in the range of C2 to C6

This device is capable of detecting compounds such as ethane, 1,3-butadiene, benzene, and other C6 compounds, enabling air pollution control, environmental monitoring, and air quality assessment in both indoor environments and industrial processes.

Applications

  • Environmental pollution control: Monitoring air quality in urban and suburban areas.
  • Indoor air analysis: Evaluating air pollution levels in workplaces or living environments.
  • Industrial and factory emission monitoring: Assessing exhaust gases from factories, industrial zones, and environmental protection perimeters.
  • Toxic gas emission assessment: Detecting hazardous compounds such as benzene and 1,3-butadiene to ensure health and safety.
  • VOC screening in the food and beverage industry: Ensuring CO₂ gas quality used in food and beverage production.
Category:

Operating Principle

The analyzer utilizes a 6-port valve combined with a single adsorbent trap and a metallic capillary column. A flame ionization detector (FID) is integrated into the system to analyze volatile organic compounds. The capillary column is housed in a temperature-programmable oven with a gradient heating system.

A thermoelectric cooling system allows precise temperature control of the sample trap when needed, such as during ethyne analysis. The device can detect compounds at extremely low concentrations, down to 15 ppt for 1,3-butadiene in ambient air, and can analyze up to 32 compounds in a single measurement cycle.

Key Features

  • Compact and highly flexible design: All components, from the sampling port to the data storage system, are integrated into a standard 19” – 4U rack, optimizing space and ensuring easy installation.
  • High sensitivity: A detection limit of 15 ppt for 1,3-butadiene, enabling accurate analysis even at very low concentrations.
  • Portable usability: Suitable for various applications, from urban air monitoring to CO₂ gas quality assessment in the food and beverage industry.Programmable temperature oven: Precisely controls the capillary column temperature, enhancing measurement accuracy and repeatability.

Vistachrom Control Software

The Vistachrom software enables users to easily monitor, analyze, and store data on a computer. Features include:

  • Data visualization and export
  • Retention time, area, mass, or concentration calculations
  • Calibration tools, recalculations, and system configuration

Optional Enhancements

  • The airmoVOC C2-C6 analyzer can be upgraded with additional features, including:
  • Online data transmission via MODBUS / JBUS or MGS1 protocol
  • Analog signal output (4-20mA or 0-10V)
  • Automated validation/calibration system
  • 24V power supply option
  • Hydrogen and VOC-free air generators for mobile applications
  • Multi-stream sample selector (2-6 streams)

Quality Control Process

Before shipment, each airmoVOC C2-C6 analyzer undergoes at least one week of testing by the quality control department to ensure high accuracy and operational stability.

Detection Limit 15 ppt for 1,3-Butadiene or 33 ng/m³ 
Detection Range  0.5 to 100 PPB/amplification³ (standard) 
Relative Standard Deviation  < 0.3% over 48h (RT)

< 2% over 48h (Conc.) 

Results  – Data storage
– 4-20mA current output (optional)
– MODBUS / JBUS or MGS1 communication protocol (optional) 
Cycle Time  30 min standard (20 min optional) 
Gas Supply  H₂ (FID and carrier gas): 30 ml/min (2 bar inlet; 1/16″ Swagelock)
Air (FID): 180 ml/min (3 bar inlet; 1/8″ Swagelock)
Sample inlet (vacuum pump): 1/4″ Swagelock
Pneumatic valve: 90 ml/commutation 
Sample Volume  20 to 240 ml (programmable)
(Sampling time up to 40 minutes) 
Power Supply  Main: 230V / 115V or 50Hz / 60Hz
Battery: 24V (optional) 
Electrical Consumption  Mean: 150 VA
Peak: 360 VA 
Dimensions & Weight  Rack: 19″ – (4U)
Height: 180 mm
Width: 482 mm
Depth: 600 mm
Net weight: 17 kg 

TSP airmoVOC C2C6

Download

Product reviews

Review AirmoVOC C2-C6 Light Volatile Hydrocarbon Analyzer

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review AirmoVOC C2-C6 Light Volatile Hydrocarbon Analyzer
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    airmoMEDOR

    AirmoMEDOR automated gas chromatography device for analyzing and monitoring odorous sulfur compounds

    Quantification of trace amounts of odorous sulfur compounds at ppm, ppb, and ppt levels
    Find out more
    chromaS

    Automated Sulfur Compounds Analyzer – Chroma S

    Automated online analysis & monitoring of sulfur compounds: H₂S / COS / CS₂ / SO₂ / RSH
    Find out more
    Auto GCMS C10C40

    Auto GC‑MS C10C40

    Portable Ultra‑Compact GC‑MS/FID Trap System
    Find out more
    MicroVOC

    Mobile VOC Analyzer – microVOC/microBTEX

    Real-time identification and quantification of volatile organic compounds (VOCs) with high precision
    Find out more
    Hệ thống giám sát Ozone airmOzone

    airmOzone Ozone Monitoring System

    A Comprehensive Solution for Monitoring Ozone Precursors (PAMS 56) and Toxics
    Find out more
    Thiết bị phân tích hợp chất hữu cơ airmoVOC C6-C20

    AirmoVOC C6-C20 Organic Compound Analyzer

    Measurement of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) in ambient air.
    Find out more
    chromaPID

    BTEX Analyzer Using ChromaPID PID Sensor

    Analyzes and monitors volatile organic compounds (VOCs) and other related substances in air, water, or soil
    Find out more
    ChromaFID

    ChromaFID Volatile Organic Compound (VOC) Analysis System

    GC/FID for Automatic, Continuous Analysis of VOCs (from 20 ppb to ppm)
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!