EE181-L Air Temperature and Relative Humidity Sensor

Accurate, rugged, ideal for long-term, unattended applications

9 ₫

The EE181 is a rugged, accurate air temperature and relative humidity (RH) probe that is ideal for long-term, unattended applications. It includes a proprietary coating on the RH element that increases the life of the element and protects it from dirt, dust, salt, or other contaminants. A 1000 Ω PRT measures air temperature for the -40° to +60°C range. For optimum results, the EE181 should be recalibrated annually. 

Category:

Benefits and Features 

    • Well-suited for long-term, unattended applications 
    • Accurate, rugged, reliable 
    • Outstanding long-term stability 
    • Wide operating temperature range 
    • User cleanable 
    • Compact and easily interchangeable 
    • Low power consumption 
    • Compatible with most Campbell Scientific dataloggers 
Measurement Description Temperature, relative humidity
Signal Type/Output Analog voltage
Supply Voltage 7 to 30 Vdc (typically powered by the datalogger’s 12 V supply)
Average Current Consumption < 1.2 mA
Filter Description 30 μm pore size, stainless-steel mesh
Startup Time 2 s
Housing Body Material Plastic
Housing Classification IP65
Field Replaceable Chip or Recalibrate Recalibrate
Operating Temperature Range -40° to +60°C
Sensor Diameter 2.1 cm (0.83 in.)
Length 16.0 cm (6.3 in.)
Weight 290 g (10.2 oz) with 5 m cable
Air Temperature
Sensing Element 1000 Ω Platinum Resistance Thermometer (PRT)
Measurement Range -40° to +60°C
Storage Temperature Range -40° to +80°C
Output Signal Range 0 to 1 Vdc
Accuracy ±0.2°C (at +23°C)
Relative Humidity
Sensing Element Capacitance
Measurement Range 0 to 100% RH (non-condensing)
Output Signal Range 0 to 1 Vdc
Temperature Dependence Typically 0.03% RH/°C
Accuracy
  • -NOTE- Accuracy specifications include hysteresis, non-linearity, and repeatability.
  • ±(1.3 + 0.003 • RH reading) % RH (at -15° to +40°C, 0 to 90% RH)
  • ± 2.3% RH (at -15° to +40°C, 90 to 100% RH)
  • ± (1.4 + 0.01 • RH reading) % RH (at -25° to +60°C)
  • ± (1.5 + 0.015 • RH reading) % RH (at -40° to +60°C)

 

Brochures: EE181 Air Temperature and Relative Humidity Probe

Download

Manuals: EE181 Temperature and Relative Humidity Probe

Download

Product reviews

Review EE181-L Air Temperature and Relative Humidity Sensor

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review EE181-L Air Temperature and Relative Humidity Sensor

There are no reviews yet.

No comments yet

Related products

Skyspec instruments

Passive remote sensing of atmospheric particles and gases
Find out more
OPEN PATH

Open-path active remote sensing instrument

Fast and accurate spectral trace gas measurements using active spectroscopy
Find out more
Hệ thống phân tích NO2-NOx-NO ICAD Series 210DL

ICAD NO2-NOx-NO Analyzer SERIES 210DL

Patented, fast, accurate and direct nitrogen dioxide detection
Find out more
Hệ thống phân tích ICAD-HONO/NO2-200L

Icad HONO-NO2 Analyzer series 210

Patented, fast, accurate and direct hono and no2 detection
Find out more
Bộ thu thập và xử lý dữ liệu Granite 10

Granite 10 Measurement and Control Data-Acquisition System

Ideal for automotive testing applications, featuring CAN bus and CAN FD output
Find out more
Mô-đun Đầu vào Cổng Dòng điện 100 Ohm CURS100

CURS100 100-Ohm Current Terminal Input Module

Expands capabilities, allows data logger to measure additional types of sensors
Find out more
Datalogger ba kênh cho cảm biến dây rung CRVW3-NE

CRVW3-NE Three-Channel Vibrating Wire Datalogger without Enclosure

Vibrating Wire Data Logger Using patented VSPECT™ technology
Find out more
Bộ Ghi Dữ Liệu Dây Rung Ba Kênh CRVW3

CRVW3 Three-Channel Vibrating Wire Datalogger

Self-Contained Vibrating Wire Data Logger Using patented VSPECT® technology
Find out more