CS451 Stainless-Steel Pressure Transducer

Stainless Steel, ideal for long-term deployment in harsh conditions

The CS451 is a pressure transducer with a a stainless-steel case. It is used for water-level measurements and can be submerged in most canals, wells, ponds, lakes, and streams. The CS451 outputs either a digital SDI-12 or RS-232 signal to indicate observed pressure and temperature. This output can be read by many of our data loggers. 

The CS451 replaces the CS450 transducer. The new transducers have a smaller gap between the water ports and the diaphragm so that less air is trapped that the user must remove during deployment. Trapped air causes the transducer’s readings to drift as the air slowly dissolves into the water. 

Category:

The CS451 consists of a piezoresistive sensor and a temperature sensor housed in a 316L stainless-steel case. It has a rugged Hytrel cable that remains flexible, even under harsh environmental conditions. The cable incorporates a vent tube to compensate for atmospheric pressure fluctuations. The vent tube terminates inside a desiccant tube, which prevents water vapor from entering the inner cavity of the transducer. The sensor ships with a desiccant tube that can be replaced in the field. 

The CS451 has several pressure range options and two accuracy options (see Ordering Info). The standard accuracy option provides ±0.1% FS TEB over the 0° to 60°C temperature range. The high accuracy option provides ±0.05% FS TEB over the 0° to 60°C temperature range and includes a calibration certificate. TEB is the combined errors due to nonlinearity, hysteresis, non-repeatability, and thermal effects over the compensated temperature range, per ISA S51.1. Please note that the high accuracy option is not available for the 0 to 2.9 psig range option. 

Campbell Scientific offers the A150 Desiccated Case that allows the CS451 to be connected to a  prewired enclosure. 

Benefits and Features 

    • Quality construction to ensure product reliability 
    • Rugged stainless-steel case protecting the piezoresistive sensor 
    • Compatible with most Campbell Scientific data loggers 
    • Fully temperature-compensated 
    • Low-power sleep state between measurements to reduce power consumption 
    • Optional weighted nose cone to facilitate submersion 
    • Optional NPT nose cone to enable usage in closed-pipe applications 
    • Quick shipment after receipt of order (ARO) 
Measurement Time < 1.5 s
Output Options SDI-12 (version 1.3) 1200 bps; RS-232 9600 bps
Water-Level Resolution 0.0035% FS
Worst-Case Temperature Resolution 0.006°C
Dry Storage Temperature Range -40° to +100°C
WARNING: Sensor could be damaged if encased in frozen ice.
Operating Temperature Range 0° to 60°C
WARNING: Sensor could be damaged if encased in frozen ice.
Temperature Accuracy ±0.2°C
Overpressure 2 x pressure range
Power Requirements 6 to 18 Vdc
Cable Type Hytrel Jacket, five conductor, 26 AWG
NPT Fitting 1/4-in. NPS
Top Cone Material Delrin
Body Material 316L stainless steel
Element Material 316L stainless steel
Distance
  • 2.54 cm (1 in.)
    Distance from black line etched on housing to end of NPT fitting
  • 2.3 cm (0.9 in.)
    Distance from black line etched on housing to end of standard nose cone
  • 9.9 cm (3.9 in.)
    Distance from black line etched on housing to end of weighted nose cone
Ingress Protection Exceeds IP68
Diameter 21.34 mm (0.84 in.)
Cable Outer Diameter
  • 0.589 cm (0.232 in.) nominal
  • 0.599 cm (0.236 in.) maximum
Length 213.36 mm (6.875 in.)
Cable Weight 0.0421 kg/m (0.0283 lb/ft)
Weight 0.17 kg (0.37 lb) without cable
Air Gap
Standard & Weighted Nose Cone 0.653 cm (0.257 in.)
NPT Fitting 2.72 cm (1.07 in.)
Power Consumption
Quiescent < 50 µA
Measurement/Communication 8 mA (1 s measurement)
Maximum 40 mA
Measurement Ranges at Fresh Water Depths
0 to 2.0 m (6.7 ft)
  • 0 to 2.9 psig
    The high accuracy (±0.05% FS) option is not available for the 0 to 2.9 psig range option.
  • 0 to 20 kPa
    The high accuracy (±0.05% FS) option is not available for the 0 to 2.9 psig range option.
0 to 5.1 m (16.7 ft)
  • 0 to 7.25 psig
  • 0 to 50 kPa
0 to 10.2 m (33.4 ft)
  • 0 to 14.5 psig
  • 0 to 100 kPa
0 to 20.4 m (67 ft)
  • 0 to 29 psig
  • 0 to 200 kPa
0 to 50.9 m (167 ft)
  • 0 to 72.5 psig
  • 0 to 500 kPa
0 to 102 m (334.5 ft)
  • 0 to 145 psig
  • 0 to 1000 kPa
Accuracy
Standard Accuracy Option ±0.1% full-scale-range TEB
Total Error Band (TEB) includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range, per ISA S51.1.
High Accuracy Option ±0.05% full-scale-range TEB
The high accuracy (±0.05% full-scale range) option is not available for the 0 to 2.9 psig range option.

Total Error Band (TEB) includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range, per ISA S51.1.

Maximum Cable Length
SDI-12
  • ~457 m (1500 ft)
    1 sensor connected to a single port
  • 60 m (200 ft)
    10 sensors connected to a single port
RS-232 60 m (200 ft)

 

Brochures: CS451 Stainless-Steel SDI-12/RS-232 Pressure Transducer

Download

Manuals: CS451/CS456 Pressure Transducer

Download

Product reviews

Review CS451 Stainless-Steel Pressure Transducer

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review CS451 Stainless-Steel Pressure Transducer
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    Bộ ghi dữ liệu áp suất tức thời PIPEMINDER-ONE External

    PIPEMINDER-ONE External Transient Pressure Data Logger

    Suitable for wastewater, enables asset monitoring, pump performance alerts and more
    Find out more
    Bộ ghi dữ liệu áp suất PIPEMINDER-ONE Standard

    PIPEMINDER-ONE Standard Pressure Transient Data Logger

    High-resolution pressure data recording provides instantaneous and burst pressure detection
    Find out more
    Bộ ghi dữ liệu cảm biến âm thanh PIPEMINDER-ONE

    PIPEMINDER-ONE Acoustic Sensor Data Logger

    Combines acoustic and pressure monitoring for precise leak
    Find out more
    Máy nén khí cho đầu dò và cảm biến quang phổ

    Air Compressor for Spectrometer Probes and Sensors

    Provides compressed air for oxilyser, solilyser, ammolyser and spectrometer probes
    Find out more
    Thiết bị đo clo di động ChlorNet

    ChlorNet Portable Chlorine Monitor

    Provides mobile, accurate, reliable and real-time chlorine data
    Find out more
    Thiết bị đo khí Chlorine Dioxide Q45H/65

    Q45H/65 Chlorine Dioxide Transmitter

    Online water quality monitoring and control of industrial disinfection systems
    Find out more
    Thiết bị đo ozone hòa tan Q45H/64

    Q45H/64 Dissolved Ozone Transmitter

    Online water quality monitoring and control of ozonation system
    Find out more
    Thiết bị đo độ dẫn điện kiểu Toroidal Q45CT

    Q45CT Toroidal Conductivity Transmitter

    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!