microF

Accurate, portable & user friendly Formaldehyde analyzer

  • Model: microF
  • Manufacturer: Chromatotec

microF is a compact Formaldehyde analyzer which allows continuous and real-time qualification and quantification of Formaldehyde.

Applications

  • Public buildings occupational exposure verification
  • Industrial hygiene measurement
  • Chambers tests studies
  • Material emissions quantification
  • Building management
  • Medical studies
  • Aqueous solutions analysis
  • Concentrations levels continuous monitoring
Category:

Principle

microF is a compact Formaldehyde analyzer which allows continuous and real-time qualification and quantification of Formaldehyde.

  • Continuous and real time monitoring.
  • Temperature and relative humidity monitoring are included.
  • Field portable
  • Easy to use
  • Labour saving
  • Accuracy
  • Highly sensitive
  • Smart embedded software

Advantages

User friendly

  • Compact size and low weight
  • Deployment in less than 5 minutes
  • Powered by mains or battery
  • No carrier gas needed
  • High filters lifetimes due to low air sample flow rate
  • Low reagent volume & quantity of air sample are required
  • Calibration from gas/liquid formaldehyde solution
  • Compatibilty with canisters and FLEC® System

Rapid & accurate measurements

  • Real-time and continuous measurements
  • Time resolution down to few seconds
  • Detection limit lower than 10 ppb
  • No interferences
  • Gaseous & aqueous formaldehyde concentration measurement

Analysis programmation, monitoring & data logging

  • Color touch screen with standard/expert users modes
  • Sequence programmation
  • Results in near real-time
  • Temperature & relative humidity monitoring
  • Data logging for quality control
  • Complementary computer software for efficient & easy data processing

Issued from French academic research

  • Innovation from CNRS & Strasbourg University
  • Patented microfluidic device
  • Supported by EU and innovation programs

Options

  • Sampling teflon line (OD: 1/8’’; L: 150 cm); Spanner (10 – 11 mm); Printed manual.
  • 3G module
  • Report’air : online measurement reporting tool

 

Detection limit
  • 10 ppb (with default settings)
Detection range
  • 0 – 300 ppb (other range on request)
Measurement
  • Detector : PhotoMultiplier
  • Temporal resolution : 1 to 120 seconds
  • Response time : 10 minutes (with default settings)
  • Condition : Gas T°: 5 – 40°C; Gas RH: 20 – 80%; Atmospheric pressure
  • Calibration : Gaseous Formaldehyde or liquid solution

Sampling

  • Method : Continuous flow
  • Gaz flow rate : 0 – 30 mL min-1 (default setting 20 mL min-1)
  • Gas flow rate uncertainty : ± (1.5% Read + 0.5% Full Scale)
  • Liquid flow rate : 0 – 400 μL min-1 (default setting 20 μL min-1 )
  • Supply connection : 1/8’’ for gas; 1/16’’ for liquid
Instrument supply
  • Power supply : Input 100 – 240V ±10%; 1.5 A max; 47 – 63 Hz / Output 15V; 6.67A 100W
  • Battery life : Lithium-Ion / Autonomy > 2h
  • Power consumption : max 75 w
General
  • Operational conditions : 0 – 40°C / 20 – 80% RH
  • Storage conditions : 0 – 40°C / 0 – 85% RH
  • Display : 7” TFT display; resolution 800 x 480; integrated touchscreen
  • Autonomy: 2 hours
  • Fluoride liquid autonomy: (100ml): 80 hours
Software & communication
  • Expert and standard modes; Data saving; Analysis setting, launching and monitoring; Defects and maintenance management
  • USB : Data transfer (aera, retention time, concentration)
  • Ethernet : Communication and remote control
Mobility and accessories
  • Carrier case with handle and integrated pre-cut foam for accessories
  • DNPH tubes and rings; Power supply & cable; Particle filter;
  • Filter strainer; Carrier case with pre-cut foam; Microporous tube; 100 mL bottles with each storage and analysis caps with ferrules, 1/8’’ & 1/16’’ inox caps with associated ferrules; Teflon tubes and associated ferrules; Bottle holder; Stylus.
Other feature
  • Canister & FLEC® system

TSP microF

Download

Brochure : portables analyzers

Download

Product reviews

Review microF

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review microF
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    Related products

    TDS LAB SERIES

    TDS LAB SERIES

    Advanced Thermal Desorption Spectrometry Systems
    Find out more
    máy quang trắc ngọn lửa xung

    Pulsed Flame Photometric Detector (PFPD)

    Pulsed Flame Photometric Detector
    Find out more
    Máy đo độ đục để bàn Turb 750 T

    Turb 750 T Benchtop Turbidimeter

    Simplify turbidity measurements without compromising data quality
    Find out more
    Hệ thống phân tích dòng chảy liên tục

    Flow Solution FS3700

    Continuous Flow Analyzer
    Find out more
    máy đo màu cod 910

    910 COD Colorimeter

    Single Parameter Colorimeter for COD
    Find out more
    máy đo màu clo 900

    900 Chlorine Colorimeter

    Single Parameter Colorimeter for Total and Free Chlorine
    Find out more
    máy đo màu cầm tay

    pHotoFlex

    pHotoFlex Colorimeters
    Find out more
    máy quang phổ 9800

    9800 Photometer

    Portable & Multiparameter Photometer for Water Quality Testing
    Find out more

    Subscribe to Content

    If you need to copy the content, please leave your information, and we will respond as soon as possible. Sincerely, thank you!